No. in
the
picture
Button name
Function
1
POWER
Turning the device on/off (when turned on, the
device works with the default settings: time to start
ozone production: 1 minute; when turned off, the
fans run with a 1-minute delay).
2
OZONE /
OZONE˄ or
OZONE ˅
Choosing one of the four levels of ozonation
efficiency per hour: 25% (10g), 50% (20g), 75% (30g),
100% (40g).
3
TIMER
Setting the working time between 15 minutes (MIN)
- 240 minutes (MAX). Each press of the button
increases the operating time by 15 minutes.
4
INTERVAL
Selecting the work cycle to launch at equal intervals,
every 12 or 24 hours (the selected work cycle is
displayed on the screen - see number 10 in the
picture above).
On the display:
No. in
the
picture
Name
Function
5
Work area
Setting the area of the room for ozonation: 75-
1200 m
2
.
6
Working time 15-240 min.
7
Percentage of
ozone
production
25% (10g/h), 50% (20g/h), 75% (30g/h), 100%
(40g/h).
8
An indicator
light to remind
you to clean
the ceramic
plates
Clean the ceramic plates when the message
"CLEAN OZONE PLATE" appears on the display.
After cleaning, delete the message with the
"OZONE" button.
9
A light
reminding you
to replace the
ceramic plates
Replace the ceramic plates when the message
"REPLACE OZONE PLATE" appears on the display.
After cleaning, delete the message with the
"OZONE" button.
STARTING THE WORK
ATTENTION:
before starting the device, make sure that there are no people,
animals and plants in the ozonated room.
IMPORTANT:
before putting the unit into operation, seal the ozonated room well
to prevent ozone from entering adjacent rooms during operation.