19
STEP 9.
If the generator’s circuit breaker trips off during operation or setup, turn
off all circuit breakers in the breaker panel, reset the circuit breaker on the
generator, and restart the generator if necessary. Select and reconnect loads
following the procedures summarized in Step 7.
STEP 10.
To determine when utility power has been restored, check the green
status light (see Status Lights section in this manual). If the green light is
illuminated, utility power is present, and you can reconnect to the utility.
To reconnect to your electric utility:
A. Turn off your generator. Expect to hear a ‘clicking’ sound from the
GenerLink
™
unit when the power transition occurs. This is a simple
verification that normal utility service has been restored.
B. On your breaker panel, set all circuit breakers to the ‘on’ position.
C. You can now unplug the generator from GenerLink
™
. To unplug
GenerLink
™
, gently pull down on the metal locking ring at the top of the
GenerLok
™
connector. (See Diagram 5) Store your power cord in a safe
and dry location.
Diagram 5
Locking Ring
6
Frequently Asked Questions
Frequently Asked Questions
Q. Do I need a generator in order to use GenerLink
™
?
A. Yes. GenerLink
™
is an interconnection device that enables you to connect
your portable generator directly to your home’s wiring system. During a
power outage, your generator becomes your source of emergency back-up
power. GenerLink
™
is designed as an alternative to expensive transfer
switches and hazardous extension cords.
Q. How is GenerLink
™
different from a transfer switch?
A. GenerLink
™
offers several advantages over traditional transfer switches:
■
■
■
■
GenerLink
™
is installed outside your home at the electric meter in less
than 20 minutes. And, in most cases, you do not need to be at home for
the GenerLink
™
installation. Installation of a transfer switch can take
about two to three hours and requires re-wiring your home’s electric system.
■
■
■
■
With GenerLink
™
, you have the flexibility of selecting the appliances you
want to run from your home’s breaker panel, up to the capacity of your
generator. Most basic transfer switches have 6 to 8 hard-wired circuits. This
limits the number of circuits you can connect to the transfer switch.
■
■
■
■
Since GenerLink
™
uses your existing breaker panel, you can run any large
120 or 240-volt appliance up to your generator’s capacity. Your well pump,
water heater, sump pump, electric range, clothes dryer and electric
baseboard heat are just some of the appliances that can be run on a
rotation basis with GenerLink
™
. Many transfer switches and sub panels
have only one or two 240-volt circuits rated at 15 or 20-amps. Heavier
loads, such as hot water heaters and electric ranges, may not be
accommodated by these transfer switches and sub panels.
Q. Is there any potential for damage to my appliances?
A. GenerLink
™
is designed to function as an interconnection device and
serves to connect your generator to your home. There is no risk of damage
to your appliances created by the GenerLink
™
device. You should exercise
care when selecting your generator to ensure you are buying a high quality
generator.
Q. I want surge protection for my home and appliances, can I still use
GenerLink
™
?
A. Yes, GenerLink
™
is now available with an optional feature – surge
protection. GenerLink
™
with surge protection will protect your home and
wired appliances from surges over 600 volts.