background image

9

Low temperature start delay

(When the internal temperature

of charger is between -20 to -30

° C, the charger will delay

starting for 1~2 minutes)

R-G-Y-Y -Y-Y-Y-Y-Y-Y---

Note

1."-" represents led that does not light for 0.5s, a color word represents that

the LED of this color lights for 0.2s.

2. R --red   G —green  Y—yellow

IX Methods of Operation

(1) Connect the output terminal of the charger to the battery terminal

(2) Connect the input plug of the charger to AC power socket until the charger turns into normal charging process (observe the LED Indicator), then Charger

will automatically charge the batteries. When fully charged, the charger will automatically shut down, and display ‘full power’.

(3) If observed the battery become overheating or ballooning during charging process, you should stop the charger immediately by unplug the plug from the

AC socket.

X Appearance and Installation Dimensions

CH4100 Series High Efficiency Intelligent Charg...

http://www.ukeasypower.com/En/Product_Detail....

6 of 8

11/19/2015 11:13 AM

Содержание CH4100 Series

Страница 1: ...ion Description 10 IX Methods of Operation 12 X Appearance and Installation Dimensions 13 XI Faults solutions 14 I Product Overview CH4100 series high efficiency intelligent charger is designed to charge power batteries of electric vehicles This series of products adopt the most advanced technologies such as LLC resonant active power factor correction microcomputer measurement and control digital ...

Страница 2: ...ected to AC power supply with extension cables please make sure that the extension cable can withstand the maximum input current GB 2 5mm2 copper core cable is recommended to be used and limit the extension cable length within 10m 5 Don t place the charger in water or rain position otherwise there is a danger that may cause electric shock and damage to the charger 6 The charger s DC output plug sh...

Страница 3: ...he appearance of battery is not ballooning the battery is not overheating when charging IV Product Models 1 Naming Rules 2 Available Product Models CH4100 4825 CH4100 4830 CH4100 4835 CH4100 6025 CH4100 6030 CH4100 6035 CH4100 6425 CH4100 6430 CH4100 6435 CH4100 7220 CH4100 7225 CH4100 7230 CH4100 9615 CH4100 9620 CH4100 9625 Note Portable versions are available for above models these models will ...

Страница 4: ... N Neutral wire 3 Yellow and green 2 5 mm2 PE Protective grounding wire Output Cables Terminal Model SB50 Needle No Wire Color Wire core diameter Description red 6 mm2 Output positive pole black 6 mm2 Output negative pole Signal Cables Needle No Wire Color Wire core diameter Description Needle No 1 brown 2 Blue DJ7031Y 2 3 21 external LED indicator interface DJ7031Y 2 3 11 3 yellow 4 purple DJ7021...

Страница 5: ... 8 Blue and white 9 Green and white 10 orange DJ7021 2 11 Forbidden signal interface normal close DJ7021 2 21 11 grey Wire core diameter 0 5 mm2 for all Signal wires Signal Cables Terminal Diagram Direction of view form the cables to terminal VIII Charging Indicator Information Description The charger installed a LED indicator internally this built in indicator display information through the wind...

Страница 6: ...al 2 Connect the input plug of the charger to AC power socket until the charger turns into normal charging process observe the LED Indicator then Charger will automatically charge the batteries When fully charged the charger will automatically shut down and display full power 3 If observed the battery become overheating or ballooning during charging process you should stop the charger immediately ...

Страница 7: ...amaged or aging Check and replace battery Battery Overheating Battery is damaged or aging Check and replace battery Pre charge timeout Battery is damaged or aging Check and replace battery Internal temperature sensor fault Charger is broken inside Please contact us Output voltage feedback fault Charger is broken inside Please contact us Full Power after short charging Battery is broken Poor contac...

Страница 8: ...t all connectors correctly and recharge Battery is broken Replace new battery LED indicator doesn t light AC input is not connected firmly Check AC power supply and chargers input cables Charger is broken inside Please contact us If your charger still cannot work correctly after above treatment please record the state of the fault phenomenon and charging indicator information then contact us Conta...