background image

To enjoy the outstanding performance from your fire pit, make sure you perform the following 

activities on a regular basis:

1. Use warm soapy water for cleaning. Never use flammable or corrosive cleaning agents. 

2. Remove dirt, spills or stains on the product quickly. 

3. Dry the product with a soft cloth or paper towel.

4. Do not use sharp tools to scratch the product.

5. While cleaning the fire pit, make sure to keep the area around the burner dry at all times. DO NOT

    submerge the control valve assembly. If the gas control is submerge in water, DO NOT use it.

     It must be replaced.

6. Air flow must be unobstructed. Keep controls, burner, and circulating air passageways clean. 

    Signs of possible blockage include:

    (1). Gas odor with extreme yellow tipping of flame.

    (2). Fire pit does NOT reach the desired temperature.

    (3). Fire pit flame is excessively uneven.

    (4). Fire pit makes popping noises.

    (5). Spiders and insects can nest in burner or orifice. This dangerous condition can damage fire 

            pit and render it unsafe for use. Clean burner holes by using a heavy-duty pipe clearer.

           Compressed air may help clear away small particles. 

7. Carbon deposits may create a fire hazard. Clean burner with warm soapy water 

    if any carbon deposits develop.

8. Cover your fire pit with an outdoor weather cover when not in use to protect it  from the elements.

    NOTE: Always allow fire pit to cool COMPLETELY before you cover the fire pit  with an outdoor

    weather cover or you attempt the service or maintenance.

9. NOTE: Always dry the product completely before it is covered or stored into the garage.

Observe Flame Height When Lit: 

The burner will display blue and yellow flames. These flames should be a blue / 

yellow color between 1~2 in. height, (See Figure 12). These flames should not be yellow or produce thick smoke. 

This would indicate an obstruction of airflow through the burners. The flames should be blue with straight yellow tops. 

If excessive yellow flames are detected, turn off the burner and consult “Troubleshooting".

08

Figure 12

CARE AND MAINTENANCE

 

 

 

Yellow

Yellow

Light Blue

Light Blue

Blue

Blue

 

Good

Bad

Содержание F200060-A1

Страница 1: ...supplier DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a c...

Страница 2: ...the control compartment burners and circulating air passageways of the appliance are kept clean CAUTION The propane gas pressure regulator provided with this appliance must be used This regulator is...

Страница 3: ...ely 18 in Tank Body approximately 12 in diameter Base approximately 8 in diameter The cylinder supply system must be arranged for vapor withdrawl The cylinder used must include a collar to protect the...

Страница 4: ...or pop the first time it is used The lava rock has been pre heat treated to release any natural inherent moisture How ever in rare cases on first time use the lava rock may pop or burst causing small...

Страница 5: ...or in an area where the hose may be subject to accidental damage Figure 3 Figure 4 3 Put the gas tank in the tank seat B connect the regulator screw the black handle clockwise to tighten turn the blac...

Страница 6: ...fuera Espere 5 minutos antes de intentar posici n APG apagado 06 Figure 6 BATTERY WARNING Make sure the control knob is in the OFF position Unscrew the push button cap on the ignitor module located on...

Страница 7: ...ct the solution at the connection looking for bubbles If NO bubbles appear the connection is secure If bubbles appear the connection has the leak disconnect the regulator reconnect perform another lea...

Страница 8: ...gerous condition can damage fire pit and render it unsafe for use Clean burner holes by using a heavy duty pipe clearer Compressed air may help clear away small particles 7 Carbon deposits may create...

Страница 9: ...1 2 3 4 5 6 7 Firepit pulse ignition Firepit regulator 90 degree hose 3048 mm 120 Firepit electrode 1 75 tip wire 300 mm for 30000 BTU Fire table Weather cover Firepit lava rock red 4 18 lbs F200060...

Страница 10: ...lure caused by unreasonable or abusive use Firepits that were clearance items display models or items purchased in an as is condition freight damage firepit damaged by acts of nature vandalism fire ab...

Отзывы: