MSR213U Programmer’s Manual
PM072 Rev. A
7-6
EEPROM Data Description
Byte 0
Value
Set Reader Mode
00h HID
Keyboard
01h M
Mode
02h I
Mode
Note
Value other than 00h, 01h or 02h will reset all EEPROM to default.
Byte 1
The
Polling Interval
is to set up the period of time between consecutive requests to the
reader if it has any data to transmit.
This value must be from 1 to 255 milliseconds. A value of 255ms indicates the longest time
for data transfers.
Byte 2
Maximum packet size(fixed value).
Byte 3
7 6 5 4 3 2 1 0 Meaning
Default
0/1 Tk1
1:enable
0:disable 1
0/1 Tk2
1:enable
0:disable 1
Enable
Track
0/1
Tk3
1:enable
0:disable 1
Break
code
0/1
1:send
0:no
send
1
RAW
data 0/1
1:send
0:no
send
0
RFU
0
0
Send
SS/ES
0/1
1:no
send
0:send
0
Caps
Lock 0/1
1:On
0:Off
1
Byte 4
7 6 5 4 3 2 1 0 Meaning
Default
0/1 Tk1
1:enable
0:disable 0
0/1 Tk2
1:enable
0:disable 0
Required
Track
0/1
Tk3
1:enable
0:disable 0
RFU
1
1
RFU
0
0
Control
CR
0/1
00:after
all
data
01