2.1.2 Installation instructions
– Standard Drive Thimble
STAGE 1
| To install the drive onto the vacuum system, the drive thimble will have to be removed
in order to gain access to the flange mounting holes.
How to remove the Drive Thimble:
1.
Remove 3 x M3 Grub Screws
2.
Pull End Cap away from Drive Thimble
3.
Remove Brake Ring
4.
Remove Drive Thimble. The thimble requires considerable force to decouple the magnets.
Take care not to damage the inner magnets.
5.
Keep all items removed in a safe place
Flange Mounting Holes
Drive Thimble
Brake Ring
3 x M3 Grub Screw
End Cap