STAGE 2
| Mounting the drive Flange Assembly
How to install the Flange Assembly:
1.
Use an appropriate CONFLAT Gasket
2.
Use 6 appropriate length Mounting Bolts and washers
(note: only hex head bolts can be
used)
3.
Place CONFLAT Gasket into flange counter bore
4.
Insert MD40 flange assembly
3.
Insert bolts and tighten.
Note: when tightening bolts, care must be taken not to tighten them
unevenly as this may cause the gasket not to seal properly.
CONFLAT Gasket
CF40 Chamber Port
Mounting Bolts
Flange Assembly