7
Note: If the Servo decoder is not programmable by CV Programming (because it is
being operated in Motorola Format) steps 1-8 for an output must be carried out by
key programming. For this the DCC format must be selected in step 2.
Connection of the servo decoder for programming
For programming the servo decoder it must be
individually
connected to a
programming track. The desired servos are connected to outputs which are to be
programmed.
Configuring the Servo decoder
CV119 determines various settings of
decoder:
If the power on the different servo outputs is
always switched on, or only during servo
operation and if the operating mode is
Motorola or DCC.
The entered value is calculated from the CV
table in which the values of the desired
functions are added.
Example
Output 1 power always on
value = 1
Output 2 power always on
value = 2
Output 3 power always on
value = 4
Output 4 power always on
value = 8
Operating mode DCC value = 0
Sum of all values is always 15.
This value is preset in CV 119 by the factory.
Bit Function of CV119
Wert
0
Power output 1
only switched on during
servo operation
always switched on
0
1*
1
Power output 2
only switched on during
servo operation
always switched on
0
2*
2
Power output 3
only switched on during
servo operation
always switched on
0
4*
3
Power output 4
only switched on during
servo operation
always switched on
0
8*
7
Operating Mode
DCC
Motorola
0*
128