11
Configuration of Servo outputs
CV for servo output
Factory defaults
1 2 3 4
Description Value
Range
1 2 3 4
120 130 140 150 1.
Address
high
byte
0-8
0 0 0 0
121 131 141 151 1. Address low byte
0-255
1*
3*
5*
7*
122 132 142 152 Stop position “red” Address 1
0-127
30
30 30
30
123 133 143 153 Stop position “green” Address 1
0-127
95
95 95
95
124 134 144 154 Switchover
time
0-255 40 40 40
40
125 135 145 155 Relay Switching point setting “red”
0-2
0
0
0
0
126 136 146 156 Relay Switching point setting “green”
0-2
0
0
0
0
160 170 180 190 2.
Address
high
byte
0-8
0 0 0 0
161 171 181 191 2. Address low byte
0-255
0
0
0
0
162 172 182 192 Stop position “red” Address 2
0-127
0
0
0
0
163 173 183 193 Stop position “green” Address 2
0-127
0
0
0
0
*) When a Motorola center is used the factory programmed addresses are not usable and must be adjusted by the
user via key programming.
Guarantee declaration
Each component is tested for its complete functionality before distribution. If a fault
should arise within the guarantee period of 2 years, we will repair the component
free of charge upon production of proof of purchase. The warranty claim is void if
the damage was caused by inappropriate treatment.
The trade names mentioned are registered trade marks of the respective companies.
02045
8583-27
If you have any questions call us. Hotline times are:
Mon - Tue - Thu - Fri, 14:00-16:00 and Wednesdays 16:00-18:00
Our products are covered by a two year warrantee. If it is defective send decoder along
with the receipt of purchase to the following address:
Uhlenbrock Elektronik GmbH * Mercatorstr. 6 * 46244 Bottrop
Tel: 02045-8583-0 * Fax: 02045-8684-0 * www.uhlenbrock.de