The 0-10V control type needed in the Vega illuminator is current source, not current sink. The
unit relies on the control unit to supply the 0-10V control voltage.
There are three connections required - the fiber port, the mains supply cable and the 0-10V
control cable. The fiber port should be connected first. Connect and secure the fiber optic
connector into the collar and secure using the M5 locking screw.
Connect the PSU to the DC input jack socket on the illuminator, and connect the IEC plug to the
PSU. Plug the mains plug into the electrical supply socket. Switch on power – the red LED
Indicator will illuminate and the illuminator is ready for use. If no light is produced consult the
TROUBLESHOOTING section of this user guide.
THE LIGHT SOURCE WILL NOT ILLUMINATE UNLESS DIP SWITCH 10 IS ON AND A 0-10V
SIGNAL IS PRESENT
Connect the 0-10V control cable(s) to the Mini-XLR socket(s) on the rear of the illuminator. The
recommended plugs for these sockets are Multicomp SVP556-TA (female) or Multicomp SVP555-
TA (male). The pin out details for these plugs are shown below.
Either socket may be used as 0-10V IN or 0-10V OUT
CONNECTION
-
VEGA
C
0-10
V
AND
T
0-10
V
MODELS
ONLY
Note:
UFO can supply converters for these illuminators to allow them to be interfaced to
standard 3 pin XLR connectors or RJ45 connectors.