PROCEDURES
FOR
ALL
MODEL
TYPES
Problem
Possible Cause(s)
Remedy
Unit is dead –
no light output
and LED power
indicator on
PSU is not
illuminated
Mains supply o
ff
Check supply & reinstate
Loose mains plugs
Check plugs
Plug fuse blown (UK)
Check fuse. If blown, replace
PSU failed
Replace PSU
Unit is dead –
no light output
and LED power
indicator on
PSU is illumi
nated, but LED
indicator on Illu
minator not
illuminated
PSU failed
Replace PSU
Note:
Please complete relevant troubleshooting procedures before returning the unit to us for
further investigation.
Problem
Possible Cause(s)
Remedy
Unit is dead –
no light output
but LED power
indicator is
illuminated
Dimming control at minimum
adjust
Adjust brightness on dimmer
control at rear
Dip switch no. 10 not switched
on
Remove cover and switch dip
switch no. 10 to on
LED array or drive failure
Replace illuminator
ADDITIONAL
PROCEDURES
FOR
MANUAL
DIMMING
MODELS
Poor light
output on
fi
ber
Illuminator dimmed either
manually or by DMX or 0
10V
control
Check and increase dimmer
se
tti
ngs as appropriate
LED driver failure
Replace illuminator
TROUBLESHOOTING
11