ADDITIONAL
PROCEDURES
FOR
DECORATIVE
MANUAL
MOTOR
MODELS
Note:
please complete relevant troubleshooting procedures before returning the unit to us for
further investigation.
Problem
Possible Cause(s)
Remedy
Decora
ti
ve
wheel not
turning
Motor control at minimum
Adjust motor control at rear
Dip switch no. 10 not switched
on
Remove cover and switch dip
switch no. 10 to on
Driver circuit or motor failure
Contact UFO
Problem
Possible Cause(s)
Remedy
Not responding
to DMX control
Dip switch no. 10 is switched on
Remove cover and set dip switch no. 10
to o
ff
DMX address not correctly set
Remove cover and set correct address
No DMX signal from controller
Check DMX controller for correct se
tti
ng
Wiring fault on DMX cables
Check cables and repair as required
Driver circuit failure
Contact UFO
ADDITIONAL
PROCEDURES
FOR
DECORATIVE
DMX
MODELS
Problem
Possible Cause(s)
Remedy
No 0
10V signal
present
Dip switch no. 10 is switched
o
ff
Remove cover and switch dip
switch no. 10 to on
No 0
10v signal at light source
due to cable or controller fault
Check input to light source using
a DMM set to correct range
rec
ti
fy cable / controller fault