Mercury Light Source Range
12
TROUBLESHOOTING
Problem
Probable Causes
Remedy
Unit is dead – no light
output and LED power
indicator on PSU is not
illuminated
Mains supply off
Check supply & reinstate
Loose mains plugs
Check plugs
Plug fuse blown (UK)
Check fuse. If blown, replace
PSU failed
Replace PSU
Unit is dead – no light
output and LED power
indicator on PSU is
illuminated, but LED
indicator on Light Source
not illuminated
PSU failed
Replace PSU
Unit is dead – no light
output but LED power
indicator is illuminated
DMX dimming at minimum
(for DMX version only)
Adjust brightness on
controller (increase value up
from 0)
DMX fault on controller or
DMX cable
Remove DMX XLR plug from
rear of light source. Light
source wil default to full
bright. Repair DMX controller
or cabling.
LED Array failure
Replace Light Source
Unit not responding to DMX
commands
Address incorrect
Check the address set on
unit matches the address set
on the controller
DMX cable fault
Refer to manual diagram for
correct wiring termination.
Carry out continuity check
Swap DMX cable for known
good cable
Содержание UFO MER3000M