background image

Universal Fibre Optics

9

OPERATION

Remote Range Walk Test

Once the Light Source is fully installed carry out a complete range walk test and record the range in the
table below. This information is essential for maintenance purposes to determine if the
range/sensitivity is reducing and also to record dead areas within the Remote Controller’s range due to
RF obstructions and/or RF interference.

NOTE:

Where a Light Source has more than one Remote Control, reduction in operating range may be

experienced when both (or multiple) Remote Controls are used simultaneously. 

Description

Date

Max Range

Controller 1

Controller 2

Controller 3

Dead Areas

Содержание NOVA DMX

Страница 1: ...R UFO NOVA DMX T UFO NOVA DMX TR Please read this manual fully before installing operating or performing maintenance on the light source unit Issue 6 Revised 300517 Universal Fibre Optics Home Place...

Страница 2: ...are suitable for use with either glass or polymer fibre optic harness The Nova is powered by a 100 240 VAC remote desktop power supply unit IMPORTANT THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH...

Страница 3: ...LY REQUIREMENTS The LED Light Source is powered from a multifunction multi voltage desk top Power Supply Unit Remove the 24V Desk Top PSU from its box This PSU is an IEC input device catering for UK E...

Страница 4: ...uminate and the light source is ready for use If no light is produced consult the TROUBLESHOOTING section For DMX control connect up the DMX control cables to the XLR sockets on the rear of the Light...

Страница 5: ...DMX will mimic whatever standalone programme the Master Light Source is set to All menu functions are available in Master mode Note for master slave to operate both master slave units must be set to a...

Страница 6: ...uch the remote control buttons when inserting the batteries it WILL e ect the operation of your Remote Control If you do accidentally touch any of the buttons remove the batteries and start again Once...

Страница 7: ...Speed REMOTE CONTROLLER OPERATION Matching Remote to Light Source Remove the power plug from the rear of the Light Source then replace and once the Indicator Light 4 lights touch button 5 within 3 se...

Страница 8: ...White 8 2 Colours snap change Adjustable Adjustable Blue White 9 2 Colours snap change Adjustable Adjustable Green White 10 1 Colour Flash Adjustable Adjustable Red 11 1 Colour Flash Adjustable Adjust...

Страница 9: ...e purposes to determine if the range sensitivity is reducing and also to record dead areas within the Remote Controller s range due to RF obstructions and or RF interference NOTE Where a Light Source...

Страница 10: ...PROGRAMMING Nova Light Source Range 10...

Страница 11: ...Universal Fibre Optics 11 PROGRAMMING...

Страница 12: ...tween colours 1 2 3 4 5 6 7 Display colour for adjustable time display timer and then fade slowly to next colour P12 Fade colour change between colours 2 3 4 5 6 7 Display colour for adjustable time d...

Страница 13: ...RATION DMX Channel Operation The Nova DMX occupies 6 DMX channels as detailed below Channel Function Values 1 Red 0 5 o 6 255 min to max 2 Green 0 5 o 6 255 min to max 3 Blue 0 5 o 6 255 min to max 4...

Страница 14: ...d reinsert batteries as per User Guide RF remote failed Replace remote Light source receiver failed Replace Light Source Not responding to DMX no rotating symbol on LCD display Light source not in DMX...

Страница 15: ...45 C Operating Environment Indoor Dry Fan 80mm 12V Crossflow LED Type Model RGBW LED Life 40 000 hours White Lumens 1435 Blue Lumens 315 Green Lumens 1160 Red Lumens 700 Control Functionality Manual...

Страница 16: ...Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel 44 0 1890 883416 Fax 44 0 1890 883062 www fibreopticlighting com...

Отзывы: