10
EN
Specifications
DH1UF18M
DH1UF21M
DH1UF24M
Rated power
[kW]
18
21
24
Rated voltage
[V]
400 V 3~
400 V 3~
400 V 3~
Economy setting 1
1st stage
[kW]
6
7
8
2nd stage
[kW]
12
14
16
Intensive setting 2
1st stage
[kW]
9
10.5
12
2nd stage
[kW]
18
21
24
Switch-on point
1st stage
[l/min]
4.0
4.5
5.0
2nd stage
[l/min]
5.0
5.8
6.6
Mixed water at rated power
approx. 38 °C
[l/min]
9.9
11.6
13.2
approx. 50 °C (supply temperature 12 °C)
[l/min]
6.8
7.9
9.1
Minimum flow pressure of appliance*
with flow limiter
[MPa (bar)]
0.07 (0.7)
0.08 (0.8)
0.09 (0.9)
without flow limiter
[MPa (bar)]
0.04 (0.4)
0.05 (0.5)
0.06 (0.6)
Operative range in waters
of specific electric resistance at 15 °C
[Ωcm]
≥ 1300
≥ 1300
≥ 1300
Rated pressure
[MPa (bar)]
1 (10)
1 (10)
1 (10)
Maximum permissible supply temperature
[°C]
20
20
20
Energy efficiency class
A
A
A
Load profile
S
S
S
Annual energy consumption
[kWh]
481
483
483
Daily energy consumption
[kWh]
2.215
2.228
2.232
Sound power level
[dB]
15
15
15
Hot water heating energy efficiency
[%]
38.4
38.2
38.1
* Plus any pressure loss at the tap mixer
C
Dimensions
Special accessories
■
BZ45U20 Pipe set: for use of the continuous-flow heater
as an under sink appliance
■
Priority switch (load shedding relay) BZ45L21:
for operation with the priority circuit
■
Mounting set BZ45K23: for surface-mount installation
Содержание DH1UF18M
Страница 13: ......
Страница 16: ...2 2 2 1 1 1 max 16 mm III...
Страница 18: ...min 40 mm 0 mm PE L3 L2 L1 min 40 mm 2 RESET 1 L1L2L3PE 7 3 5 4 V...
Страница 19: ...2 3 4 1 VI L 3 L 2 L 1 3 2 1 PE PE B 1 2 3 4 A...
Страница 20: ...G 1 2 A 375 39 472 124 136 236 100 42 204 140 C D 1 2 3 E...
Страница 31: ...23...
Страница 32: ...BSH Hausger te GmbH Carl Wery Stra e 34 81739 M nchen Germany 6 720 820 345 9001217914 2016 DE EN ES PL...