Battery Indicators

The thermometer incorporates visual low battery
indications.

:

Battery OK

” measurements 

are possible

:

Battery Low

” battery needs to be 

replaced, measurements are 
still possible

:

Battery Exhausted

” measurements 

are not possible

M a i n t e n a n c e

Periodic Service

WARNING!

Repair and service of this instrument is to be performed by qualified
personnel only.

Cleaning

Pe r i o d i cally clean your instrument’s case using a damp cloth. 

DO NOT

use abrasive, flammable liquids, cleaning solvents, or strong detergents as
they may damage the finish, impair safety, or affect the reliability of the
s t r u c t u ral components.

Battery Replacement

Always use a fresh replacement battery of the specified size and type.
Immediately remove the old or weak battery from the meter and 
dispose of it in accordance with your local disposal regulations. Old or
defective batteries can leak chemicals that corrode electronic circuits.

To replace the battery:

1. Slide the battery cover straight down then away from the 

INF185/215 (Fig 2).

2. Replace with fresh “AAA” (2x) batteries.

3. Replace cover.

Additional Features

Changing Scales

To change scales between degrees Fahrenheit and degrees Celsius,
press the button on the panel, (marked °F / °C), while the display is
active. Even if the trigger is released and the display is in its 60-second
automatic hold, you can convert the reading between scales. Each time
you press the scale button, the 60-second hold will reset. The INF155
will default to the scale last used the next time it is turned on.

Using the Laser Sight

The INF185/215 is classified as a "Laser Product", and is regulated by
the FDA.

WARNING!

Using controls, making adjustments, or performing procedures in any
manner other than that specified herein may result in hazardous 
radiation exposure.

LCD Error Messages

The thermometer incorporates visual diagnostic messages as follows:

:

H i

” or “

L o

” is displayed when the temperature being 

measured is outside the settings of HAL and LA L .

:

E r 2

” is displayed when the thermometer is exposed to 

rapid changes in the ambient tempera t u r e .

:

E r 3

” is displayed when the ambient temperature exceeds 

the operation range of 32˚ to 122˚F (0˚ to 50˚C). The 
thermometer should be allowed plenty of time (minimum 
30 minutes) to stabilize to the working/room tempera t u r e .

:

For all other error messages it is necessary to reset 
the thermometer.

To reset the thermometer, turn the instrument off, remove the battery and
wait for a minimum of one minute. Reinsert the battery and turn it on. If the
error message remains please contact UEi service department for 
further assistance.

INF185/215-MAN    

P. 3

(Fig 2)

“AAA” (x2)

Perform this first

Verify that the meter

Press to activate the following

is in one of these modes

Press and release

In MIN, MAX, DIF, 

LOCK

- Press the “      “ push-

the trigger to activate

AVG mode

button for LO CK mode ON/OFF

display first

-  This locks the IR measurement
for up to 60 minutes

SCA L E

- Press “      “ push-button to 

select ˚C or ˚F 

Press and release

In all modes

BACKL IGHT / WORKL IGHT 

the trigger to use

Press the “      “ p u s h - b u t t o n

these functions

for backlight function ON/OFF

LASER

- Press the “      “ push-

button for laser function ON/OFF