10
Non-Contact Voltage
NCV Sensor in the tip.
30V
T
1
TEMP
T
2
True RMS
DL589
PEAK
µA
Temp
600V
600A
CAT IV
V
A
SELECT
Low Z
AUTO
V
A
• Rotate Rotary Selector Dial to
NCV
position move the tip of the clamp meter
near voltage source.
• Non-Contact Voltage Detection is used to detect power with sensor located
in the tip of the clamp head, indicates positive response with both an
Audible and Visual alert.
• Do not use Non-contact voltage detector to determine if there is current on
the wire. Detection operation could be affected by socket design, insulation
thickness, type or other factors.
• Voltage indicator light may also light when voltage (>AC/DC 30V) is present
on the meter’s input jack or from an external interference such as motors,
flashlights, etc.
Features:
On Voltage
Approx. 24V AC