background image

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

Prs/Temp

O2 20.9%
CO 

  0P

C02 8.3%
XAIR  42.4%
PRS -0.02i
Ta 80.3F

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

MENU
SETUP
UNITS
SCREEN
REPORT
SERVICE

Prs/Temp

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

ROOM CO 
TEST 1/15
INT. 120s
CO 5p
LIMIT 10p
ALARM 30p

Prs/Temp

REPORTS: 

PRINTING & VIEWING

HIGH CO ALERT

Press 

 ”Print” to start 

printouts of results from any 

test screen.
Press

 

 during printing to 

cancel.

Press and hold 

 to log 

current readings.
Align printer above Analyzer.

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

NAT GAS
Ra 0.0010 
CO  

  80P

C02 8.3%
XAIR 42.4%
PRS 0.03m

Prs/Temp

To view test results, 

rotate dial to 

Menu

.

Scroll

or

 to 

Report

 

Press 

 to select.

Scroll 

 or

 

 to type 

of test wanted.
Press 

 to select. 

[Exchange shown]

Press 

 to select 

View

.

Press 

 to select 

report log number. When 

indicator lights blink, 

use  

 or

 

 to scroll 

through logged reports. 
Press 

 to view a 

selected report log.

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

NAT GAS
Ra 0.0010 
CO  

  80P

C02 8.3%
XAIR 42.4%
PRS 0.03m

Prs/Temp

At 1000 ppm CO the screen will display 

HIGH CO

 and an indicator light will flash and analyzer will beep several times. Above 2000 ppm the purge pump starts. 

Print and Log easily from the following test screens: Aux, Flue 1, Flue 2, Commission Test, Pressure/Temperature, Exchange Test and Room CO

CO ROOM TEST

No probes or hose connections 

required for this test.
Rotate selector dial to 

ROOM CO

.

Press

 

”Print” to

 

start the 

 

GENERAL

 test.

Press 

 

start the test.

CO readings will be logged every 2 

minutes for a 30 minute time span.
Readings will be stored once the 30 

minute test is completed.

Press 

 to print results. 

Test results will automatically be 

stored in 

ROOM CO

 reports.

See 

REPORTS

 section in this guide.

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

ROOM CO 
LOG No.  1 
TEST 1
CO 5p
GENEAL
PRINT 

Prs/Temp

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

SELECT
ROOM CO 
TEST TYPE
GENERAL

Prs/Temp

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

ROOM CO 

PRESS
TO
START

Prs/Temp

Great for checking ambient CO and back drafting situations

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

MENU
SETUP
UNITS
SCREEN
REPORT
SERVICE

Prs/Temp

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

SCREEN

CONTRAST
BACKLIGHT
AUX
BACK

Prs/Temp

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

AUX

LINE 1
LINE 2
LINE 3
LINE 4
LINE 5

Prs/Temp

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

SCREEN

AUX
LINE 5
PRS 0.02i

Prs/Temp

AUX SETTING 

Rotate selector dial to 

Menu

.

Scroll 

 or

 

 

to 

Screen

.

Press 

 ”Print” to select.

Scroll 

 or

 

to 

AUX

.

Press 

 

to select.

Scroll 

or

 

to customize 

any Line.
Press 

 

to select.

[Line 5 shown]

Scroll 

 or

 

to select 

the parameter for this line.
Press 

 

to select.

[Pressure shown]

Rotate selector dial to 

AUX

 

to view.
Custom selections will now 

display in 

AUX

 mode.

Programmable Auxiliary screen allows for Tech selectable test parameters to be chosen.

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

REPORT

AUX
COMBUSTION 
COMBUSTION
PRS/TEMP
EXCHANGE

Prs/Temp

Menu

Room CO

Status

Aux

Flue1

Flue 2

C165

Com Test

Exch Test

LOG No. 9
12:00:00
CO 0p 
02 20.9%
XAIR O2++%
PRINT

Prs/Temp