FRENCH WARNING TRANSLATIONS

Page

Warning Text

Texte d’advertissement

1

Misuse of this product may cause explosion 
and personal injury. These instructions must be 
thoroughly read and understood before unit is 
installed. See the product nameplate information 
for specific agency certifications applicable to 
your product.

Utilisation abusive de ce produit peut causer une explosion et des blessures. 
Ces instructions doivent être soigneusement lues et comprises avant l’ appareil 
est installé. Voir l’information sur la plaque signalétique du produit pour les 
certifications d’agence spécifiques applicables.

1

Substitution of components may impair suitability 
for use in hazardous locations. 

La substitution de composants peut nuire à l’aptitude à l’utilisation dans des 
endroits dangereux. 

1

For zone hazardous locations, all cable entry 
devices shall be certified in type of explosion 
protection flameproof enclosure “d” with an 
IP66 rating suitable for the conditions of use and 
correctly installed. If cables and cable glands are 
not used, a stopping box shall be provided within 
2” of the enclosure. Flameproof joint and gap 
details are provided on page 2. 

Pour les zones explosives poussiéreuses, tous les dispositifs d’entrée de câble 
doivent être certifiés dans le type de protection de l’ enceinte ignifuge “d” avec 
un indice de protection IP66, adapté aux conditions d’utilisation et correctement 
installés. Si les câbles et presse-étoupes ne sont pas utilisés, une boîte d’arrêt 
doit être fournie dans les 5 cm de l’enceinte. Plus de détails sont fournis à la 
page (2).

1

Install units where shock, vibration and tem-
perature fluctuations are minimal. Orient unit to 
prevent moisture from entering enclosure. Use 
properly rated sealing fittings for electrical wire 
entry. Do not mount unit in ambient temperatures 
exceeding published limits. This is especially 
critical for local mount temperature units. Use of 
a shroud is recommended where direct sunlight 
and rain may come in contact with the enclosure.

Installez les unités où le choc, vibration et les fluctuations de température sont 
minimes. Orienter l’unité d’une manière à empêcher l’humidité de pénétrer 
dans l’enceinte. Utiliser des raccords d’étanchéité bien notés pour l’entrée de fil 
électrique. Ne pas monter l’unité à des températures ambiantes dépassant les 
limites publiées. Cela est particulièrement important pour les unités de tem-
pérature à montage locale. L'utilisation envelopper est recommandée lorsque le 
soleil et la pluie peuvent entrer en contact avec le boîtier.

1

In order to meet the electromagnetic compatibility 
requirements specified in EN61000-6-2: Im-
munity for Industrial Environments, external wiring 
must be run using cable with a grounded shield 
or cable run inside of a grounded metal conduit. 

Afin de répondre aux exigences de compatibilité électromagnétique spécifiées 
dans EN61000-6-2: Immunité pour les environnements industriels, le câblage 
externe doit être exécuté en utilisant un câble avec un bouclier à la terre ou 
longueur de câble à l’intérieur d’un conduit métallique.

1

Interference from improperly shielded VFD’s 
(Variable Frequency Drives) and motor control-
lers may cause nuisance trips. 

Les interférences provenant de VFD’s (variateurs de fréquence) et de con-
trôleurs de moteur mal blindés peuvent provoquer des déclenchements 
intempestifs.

2

Continuous operation should not exceed the des-
ignated over range pressure or working pressure 
range stated within the literature and on device 
nameplate. 

Le fonctionnement continu ne doit pas dépasser la pression de dépassement ou 
la plage de pression de fonctionnement indiquée dans la documentation et sur 
la plaque signalétique de l'appareil.

3

Before installing, check the sensor model 
selected for compatibility to the process media in 
contact with the sensor and wetted parts.

Avant l’installation, vérifier le modèle de l’appareil sélectionné pour la com-
patibilité avec le fluide du procédé en contact avec le capteur et les parties 
mouillées.

3

In all applications, secure the enclosure as 
detailed below. Do not mount via the process 
connection only. 

Dans toutes les applications, sécuriser l’enceinte comme détaillé ci-dessous. Ne 
pas installer par la connexion de processus seulement.

4

For pressure and local temperature models, 
always hold a wrench on the sensor housing hex 
when mounting the device. Do not tighten by 
turning the enclosure, as this will damage the 
connection between the sensor and housing. 

Pour tous les modèles de température et pression locaux, toujours tenir une 
clé sur l’hexagone du capteur pendant le montage de l’unité. Ne pas serrer en 
tournant l’enceinte, cela pourrait endommager la connexion entre le capteur et 
l’enceinte.

Содержание 2SLP

Страница 1: ... HAZARDOUS AND THE FOLLOWING HAZARDOUS LOCATIONS AND IS ATEX AND IECEX CERTIFIED SUITABLE FOR APPROPRIATE USE IN GAS AND DUST ZONE 1 APPLICATIONS Model 2SLP N America Europe International Flameproof Cert Number UL File E226592 DEMKO 09 ATEX 0813748X IECEx UL 08 0017X Applicable Standards UL 50 UL 50E UL 61010 1 UL 1203 CSA C22 2 No 25 1966 CSA C22 2 No 30 M1986 CSA C22 2 No 94 01 07 CSA C22 2 No 9...

Страница 2: ...Series transmitter switch product line is based on an all solid state electronic module that incorporates a microprocessor The One Series Field Safety System is a loop powered all in one device connected directly to the final element and replacing a transmitter safety relay trip amplifier and logic solver It has an embedded high capacity programmable safety relay that provides extremely fast respo...

Страница 3: ...By pushing the right g button once the display will scroll as follows SP1 XX XX DB1 XX XX SP2 XX XX DB2 XX XX By pushing the left 2 button once the display will scroll the min max process values recorded in memory MAX XX XX MIN XX XX The display will automatically revert back to the Process Display mode after scrolling ALARM CONDITION When the process goes beyond the set point the display will beg...

Страница 4: ...ure that the sensor housing will not be damaged and where the measured temperature is representative of the surrounding environment For Local Spring Loaded model T A suitable thermowell made from corrosion resistant material 5 threads engaged minimum with thread sealant is required to maintain enclosure type 4X IP66 For Remote Sensing Route the extension wire to avoid contact with live components ...

Страница 5: ...oved Tools Required Small flat head screwdriver wire strippers TO PREVENT IGNITION DISCONNECT POWER BEFORE REMOVING ENCLOSURE COVER KEEP COVER TIGHT WHILE IN OPERATION DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS DO NOT REPLACE COMPONENTS UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS THE DEVICES SHALL BE PROPE...

Страница 6: ... diagnostics to determine the integrity of the SRO wiring and if the SRO is functioning properly NOTE As an alternative to loop power model 2SLP may be wired directly to a 24 VDC power supply and minus terminals In this wiring configuration power is provided for all switching and diagnostic functions but a 4 20 mA output is not possible This alternative method of powering the One Series Field Safe...

Страница 7: ...ut function as normal NOTE The 4 20 mA analog signal is not possible in this wiring configuration In this configuration the 4 20 mA output and IAW Output are monitored by the safety system logic solver The final element is controlled by the logic solver Total wire connections 4 The 4 20mA signal is used by the logic solver to initiate the safety function IAW provides a separate indication of devic...

Страница 8: ...s Field Safety System fully configured where the health status IAW and SRO switch status signals are being monitored by a logic solver PLC or DCS These connections are not required however UE recommends monitoring the IAW signal to maximize the safe failure fraction in an SIS application Additionally wiring the SRO to an external load final element is not required For direct control of a final ele...

Страница 9: ...000 0 39 714 3 1045 5 40 761 9 1090 9 No Fault Displayed 4 20 mA Normal Operating range Unused Fault 3 6 3 8 mA Normal Under range 4 20 20 5 mA Normal Over range 21 0 mA 21 0 mA only when the temperature sensor is subject to 103 25 to 110 of range or when the pressure sensor is subject to 103 25 to 150 of range Fault 0 FAULT CURRENT In addition to the discrete IAW and Safety Relay Output status si...

Страница 10: ...ft 2 button increments the blinking digit The right g button sets the digit and moves to the next Once a valid password is entered OK will appear on the display Press and release the right g button CLR MAX MIN or MAN RSET if Latch is set will appear on the display This is the first command prompt in the Programming Mode NOTE The Field Safety System will automatically exit the Programming Mode and ...

Страница 11: ... opens on falling process values that reach the set point OPEN WINDOW The Safety Relay Output opens when process values are within a specified range set by two points set point high and set point low Please use the Safety Relay Output Decision Logic Figure 13 page 12 for help with setting the appropriate Safety Relay Output mode Press and release the left 2 button until the desired mode appears Pr...

Страница 12: ...16 Resetting the Maximum Minimum Values The One Series Field Safety System continuously records the readings from the sensor and stores the minimum and maximum MAX MIN peak hold values in non volatile memory The max min values may be viewed at any time by removing the enclosure cover page 5 and pushing the left 2 button The display will scroll the MAX MIN values and then return to the Process Disp...

Страница 13: ... and change the offset Zero is the factory setting Press the left 2 button to increment the blink ing digit Press the right g button to enter and move to the next digit Press the right g button to enter the new offset and return to the main menu Adjusting Span SPAN provides an adjustment to shift the slope of the sensor s response curve to accommodate an offset value other than zero To adjust SPAN...

Страница 14: ...lity to detect that the process port may be plugged It does this by monitoring the sensor for changes over time The amount of change and the time period are programmable If the process variable does not change by the amount and selected time period the display will indicate PLUG and the IAW Output will open indicat ing a fault Refer to the Programming Flowchart on page 19 Enter the Programming Mod...

Страница 15: ...cations it is desirable to dampen the Safety Relay Output response and prevent intermittent false trips due to pressure spikes or other transient isolated events The Filter feature provides a software digital filter with a configuration time constant for sup pressing certain transient short duration events Refer to the Programming Flowchart on page 19 Enter the Programming Mode see page 10 and mov...

Страница 16: ... left 2 button to change to NEG Press the right g button to view and change the scale Press the left 2 button to increment the blinking digit Press the right g button to enter and move to the next digit This process value must be between 3 and 25 of the sensor s maximum range Press the right g button to enter the new scale and return to the main menu Setting the 20 mA portion of the scale see Figu...

Страница 17: ...pen check all sensor connections E 16 Diagnostic Fault Sensor SHORT A short circuit has been detected on the sensor drive pins 2 3 Diagnostic Fault Sensor Short check all sensor connections E 18 Diagnostic Fault Relay Monitor The relay output fault monitor circuit has detected that the output state of the solid state relay is incorrect This feature must be enabled in the menu Check the wiring conn...

Страница 18: ...E ORIGINAL DATE DRWN CHKD APPD DO NOT SCALE THIS DRAWING DOC DE733010102 Rev B EM ONE SERIES 1X NAMEPLATE A 6211 847 SR 5 14 15 6211 847 DESCRIPTION DATE DRWN APPD UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES REV ECN Figure 19 Kanban number and Date Code Set Point Reached IAW Fault SRO Status IAW Output Safety Relay Output No No Closed Closed Closed No Yes Open Open Open Yes No Open Closed ...

Страница 19: ...pend on sensor range Invalid PWORD BOTH Abort NO RESET OK Flash Err Abort BDOOR PWORD Valid SAVING SAVING One Series Field Safety System LCH1 ON OFF OFST POS NEG 8888 Set Blinking Digit Increments Blinking Digit Sets Digit and moves to next SPAN POS NEG 8888 Set Blinking Digit Increments Blinking Digit Sets Digit and moves to next Offset out of Range flash Err SPAN out of Range flash Err PLUG PORT...

Страница 20: ...OR PORT 1 2 14 NPT SENSOR PORT 1 20 NPT SENSOR PORT 1 20 NPT SENSOR PORT 111 92 mm 76 2 mm 133 35 mm 12 7 mm SURFACE MOUNTING KIT 6361 704 144 78 mm 134 62 mm 137 16 mm 154 94 mm 134 62 mm 137 16 mm 264 16 mm 203 2 mm 137 16 mm 129 54 mm 134 62 mm 137 16 mm 76 2 mm 92 20 mm 129 54 mm 134 62 mm 137 16 mm 107 95 mm 61 91 mm 158 75 mm 7 11 mm 107 95 mm 76 2 mm 6 35 mm 8 73 mm DIMENSIONAL DRAWINGS GAG...

Страница 21: ...SULATED CABLE Ø0 125 3 18 mm FOR DC UNITS Ø0 250 6 35 mm 1 2 NPT COMPRESSION FITTING 300 SERIES st st 26 AWG STRANDED TEFLON INSULATION 4 50 114 3 mm FIXED DIM EPOXY SEAL 2 00 50 8 mm FIXED DIM 1 2 14 NPT PIPE NIPPLE 300 SERIES st st 0 50 12 7 mm Temperature Sensors Remote TR1 TRC TH1 THC TC1 TCC SENSOR OPTIONS Spring Loaded Local TTC Fixed Local TL1 TL3 Differential Pressure 1 4 18 NPT MALE BOTH ...

Страница 22: ...ée de fil électrique Ne pas monter l unité à des températures ambiantes dépassant les limites publiées Cela est particulièrement important pour les unités de tem pérature à montage locale L utilisation envelopper est recommandée lorsque le soleil et la pluie peuvent entrer en contact avec le boîtier 1 In order to meet the electromagnetic compatibility requirements specified in EN61000 6 2 Im munit...

Страница 23: ... retirer le couvercle du boîtier Maintenir le couvercle fermé pendant le fonctionnement Ne pas décon necter l équipement que lorsque l alimentation est coupée ou que la zone est connue pour être non explosives 5 Do not replace components unless power has been switched off or the area is known to be non hazard ous Ne remplacez pas les composants avant que le courant soit coupé ou que la zone est co...

Страница 24: ...or personnel Electrical ratings stated in literature and on nameplate must not be exceeded Overload on a switch can cause damage even on the first cycle Wire unit accord ing to local and national electrical codes using wire size recommended in installa tion sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANTY Seller warrants that the product hereby purchased is upon ...

Отзывы: