background image

To use the 

WARBLE TONE GENERATOR

:

1.  Turn Tone Generator on by selecting either "LOW" for a low amplitude signal (usually recommended for
small containers) or "HIGH" for high amplitude.  In high, the Warble Tone Generator will cover up to

4,000 cubic feet (121.9 cu. meters) of unobstructed space.

When the Tone Generator is on, a red light (located below the recharge jack in the front) flickers.

2.  Place the Warble Tone Generator within the test item/container and seal or close it.  Then scan the

suspect  areas with the  Scanning Module in the Ultraprobe and listen for where the "warble"

ultrasound penetrates.

As an example, if the item to be tested is the seal around a window, place the Warble Tone Generator

on one side of the window, close it and proceed to scan on  the opposite side.

4.  HEADSET

      This heavy duty headset is designed to block out intense sounds often found in industrial environments so that

the user may easily hear the sounds received by the ULTRAPROBE.  To use, simply plug the headset cord into the

headset jack on the metered pistol housing, and place the headphones over your ears.  If a hard hat is to be worn, it

is recommended to use UE Systems' model 

UE-DHC-2HH Hard Hat Headphones 

which are specifically

designed for hard hat use.

A.

  For those situations in which it is not possible or difficult to wear the standard headphones

described above, UE Systems has two options available:  1.  the 

DHC 1991

 Earpiece which loops

around the ear, and  2.  the 

SA-2000 Speaker Amplifier

 which is a loud speaker that is compatible

with the Ultraprobe headphone output jack.

5.  WTG-1 WARBLE TONE GENERATOR (OPTION)

The WTG-1 Tone Generator is an ultrasonic transmitter designed to flood an area with ultrasound.  It is used for a

special type of leak test.  When placed inside an empty container or on one side of a test item, it will flood that area

with an intense ultrasound that will not penetrate any solid but will flow through any existing fault or void.  By

scanning with the  Scanning Module, empty containers such as pipes, tanks, windows, doors, bulkheads or hatches

can be instantly checked for leakage.  This Tone Generator is a WARBLE TONE GENERATOR.  This internation-

ally patented transmitter sweeps through a number of ultrasonic frequencies in a fraction of a second to produce a

strong, recognizable "Warble" signal.  The warble tone prevents a standing wave condition which can produce false

readings and provides for a consistency of testing in practically any material.

-3-

To test the condition of the Warble Tone Generator battery, set to the LOW INTENSITY position and

listen to  the sound through the Ultraprobe headphones.  A smooth continuous warbling sound should be heard.

If a "beeping" is heard instead, then a full recharge of the Warble Tone Generator is indicated.

To charge the Warble Tone Generator:

1. Use the recharger.

2. Plug the recharger cord into the recharge jack located on

 top of the front panel.

3.  Plug the recharger into the local current supply

4.  A complete charge will take 7 hours.

5.  Since there is no memory problem, the Tone Generator

 may be charged after short intervals of use.

WTG1 WARBLE TONE

GENERATOR (OPTIONAL)

Содержание VOLUME 1.3

Страница 1: ...ULTRAPROBETM 100 INSTRUCTION MANUAL VOLUME 1 3...

Страница 2: ...LTRAPROBE USERS OUR STAFF HAS YEARS OF FIELD EXPERIENCE AND IS STANDING READY TO ASSIST YOU SHOULD YOU NEED US WHEREVER YOU ARE REMEMBER WE ARE AS CLOSE AS YOUR PHONE FAX OR COMPUTER CALL 914 592 1220...

Страница 3: ...of 0 to 70 Asthedialisturnedtotheright to 0 thesensitivityoftheinstrumentincreases Asthedialisturnedtotheleft to 70 thesensitivtydecreases Alowlevelultrasoundemissionproduceslowamplitude Forthisreason...

Страница 4: ...ield It is used to block out stray ultrasound and to assist in narrowing the field of reception of the Scanning Module It also increases the sensitivity To use simply slip it over the front of the sca...

Страница 5: ...r Amplifier which is a loud speaker that is compatible with the Ultraprobe headphone output jack 5 WTG 1 WARBLE TONE GENERATOR OPTION The WTG 1 Tone Generator is an ultrasonic transmitter designed to...

Страница 6: ...s specific sensor is limited to the particular gas it was designed to sense e g helium The Ultraprobe can sense any type of gas leak since it detects the ultrasound produced by the turbulence of a lea...

Страница 7: ...method only in addition to the glove use a wipe rag to wrap around the rubber focusing probe tip Hold the rag in the gloved hand so that it actsasa curtain i e there is enough material to cover the te...

Страница 8: ...en but they will be heard This method is capable of obtaining successful leak checks in systems with leaks as low as 1x10 6 ml sec NOTE The low surface tension of the LLA is the reason small bubbles f...

Страница 9: ...e leak to be tested the thickness of the test wall and the type of material tested i e is it sound absorbant or sound reflective Remember you are dealing with a high frequency short wave signal If the...

Страница 10: ...ng tracking and corona without taking the switchgear off line to perform an infrared scan However it is recommended that both tests be used with enclosed switchgear NOTE When testing electrical equipm...

Страница 11: ...ty whereas conventional methods are incapable of detecting very slight faults As a ball passes over a pit or fault in the race surface it produces an impact A structural resonance of one of the bearin...

Страница 12: ...gy These normal microscopic disuniformities will begin to produce wear and the possibilities of small fissures may develop which contributes to the Pre Failure condition Therefore aside from normal we...

Страница 13: ...ttent traps listen long enough to gauge the true cycle In some cases this may be longer than 30 seconds Bear in mind that the greater the load that comes to it the longer period of time it will stay o...

Страница 14: ...orcesthediscagainstthe valve seat The static pressure over a large area overcomes the high inlet pressure of the steam As the steam starts to condense the pressure against the disc lessens and the tra...

Страница 15: ...s or parts of the system and make it difficult to diagnose valve leakage In this case it is still possible to diagnose valve blow through by comparing sonic intensity differences by reducing the sensi...

Страница 16: ...sound amplification is a very important feature Although there are obvious audible sounds emitted by most operating equipment it is the ultrasonic elements of the acoustic emissions that are generally...

Страница 17: ...orexceedsANSIspecificationsandOSHAstandards Transmitter Patentedwarbletonetransmission Responsetime 300m sec Ambient Operating Temperature Range 32o 120o F 0o 50o C Relative Humidity 10 95 noncondensi...

Страница 18: ...equipment with your hands or fingers Be sure to use appropriate lockout procedures when attempting repairs Be careful with loose hanging parts such as the wrist strap or headphone cord when inspectin...

Отзывы: