SAFETY ADVISORY. PLEASE READ BEFORE USING YOUR 
INTRUMENT.  

 

WARNING! 

Improper use of your ultrasonic detector may result in death or serious injury. Observe all safety 
precautions. Do not attempt to make any repairs or adjustments while the equipment is operating. Be 
sure to turn off and LOCK OUT all electrical and mechanical sources before performing any corrective 
maintenance. Always refer to local guidelines for appropriate lockout and maintenance procedures. 

SAFETY PRECAUTION. 

Although your ultrasonic instrument is intended to be used while equipment 

is operating, the close proximity of hot piping, electrical equipment and rotating parts are all potentially 
hazardous to the user. Be sure to use extreme caution when using your instrument around energized 
equipment. Avoid direct contact with hot pipes or parts, any moving parts or electrical connections. Do 
not attempt to check findings by touching the equipment with your hands or fingers. Be sure to use 
appropriate lockout procedures when attempting repairs. 

Be careful with loose hanging parts such as the wrist strap or headphone cord when inspecting near 
moving mechanical devices since they may get caught. Don't touch moving parts with the contact probe. 
This may not only damage the part but cause personal injury as well. 

When inspecting electrical equipment, use caution. High voltage equipment can cause death or severe 
injury. Do not touch live electrical equipment with your instrument. Use the rubber focusing probe with 
the scanning module. Consult with your safety director before entering the area and follow all safety 
procedures. In high voltage areas, keep the instrument close to your body by keeping your elbows bent. 
Use recommended protective clothing. Do not get close to equipment. Your detector will locate 
problems at a distance. 

When working around high temperature piping, use caution. Use protective clothing and do not attempt 
to touch any piping or equipment while it is hot. Consult with your safety director before entering the 
area. 

 

Need further support? 

Want information regarding products or training? 

CONTACT:

 

UE Systems, Inc. 14 Hayes Street, Elmsford, NY 10523 USA 

T: 

914-592-1220  |  

E:

 [email protected]  |  

W:

 www.uesystems.com

 

Содержание Ultraprobe 100

Страница 1: ...1 UE SYSTEMS INC THE ULTRAPROBE 100 MANUAL...

Страница 2: ...OVERVIEW COMPONENTS Introduction Basic Components of Your Kit Pistol Housing Scanning Module Contact Stethoscope Module Rubber Focusing Probe Long Range Module Headset WTG 1 Warble Tone Generator 2 2...

Страница 3: ...inspection through advance ultrasonic technology Before you begin testing it is advisable to familiarize yourself withthe basic components of your kit BASIC COMPONENTS OF YOUR KIT Contact Extension Ki...

Страница 4: ...er on and then stay off This is normal and has no relation to battery condition SENSITIVITY SELECTION DIAL There are eight 8 sensitivity levels which read out in related decibels of 0 to 70 As the dia...

Страница 5: ...uce the sensitivity place the RUBBER FOCUSING PROBE described below over the scanning module and proceed to follow the test sound to its loudest point If it is difficult to locate the sound due to a h...

Страница 6: ...s remove the module BEFORE attaching and removing the Long Range Module HEADSET This heavy duty headset is designed to block out intense sounds often found in industrial environments so that the user...

Страница 7: ...headphones A smooth continuous warbling sound should be heard If a beeping is heard instead then a full recharge of the Warble Tone Generator is indicated TO CHARGE THE WARBLE TONE GENERATOR Use the...

Страница 8: ...tempting repairs Be careful with loose hanging parts such as the wrist strap or headphone cord when inspecting near moving mechanical devices since they may get caught Don t touch moving parts with th...

Отзывы: