![UE Systems ULTRAPROBE 10,000SD Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/ue-systems/ultraprobe-10-000sd/ultraprobe-10-000sd_instructions-manual_834385007.webp)
10,000SD
VALVE INSPECTION
Ultraprobe 10,000SD
-
Valve Inspection:
How To Guide
NOTE:
UE DMS Software available for download at
www.uesystems.com
SAFETY: WRIST STRAP WORN ALL TIMES
INSPECTION PROCEDURE
With the
Route
Uploaded to the Ultraprobe, and the
Frequency Set to
25KHz
, Collect Data. Make
Contact
With the First Test Point Using the
A,B,C,D And
Sometimes E Method
. This Method Incorporates Four
Individual Data Points,
Two
(2)
Upstream
and
Two
(2)
Downstream
Per Valve to Uncover the
Source
of
the Ultrasonic Signal.
For Each Test Point,
Adjust and Optimize
the Sensitivity
to Capture a Decibel (dB)
Value and if Necessary, Tune
Frequency
to
Obtain a Good Quality Signal. Always Ensure
Adequate Knowledge
of the
Valve
and
Operation Prior to Inspection.
1
2
3
4