NVE40K Hardware Manual
4.3. Electrical characteristics
Specification for only Power supply
Parameter
Units
Value
Nominal Output Voltage
V
12
Maximum Output Current
A
13
Maximum Output Power
W 156
Efficiency(Typical) (*1)
100V AC
% 83
200V AC
% 86
Input Voltage Range (*2) -
85~265VAC(47~63Hz)
Input Current(Typical) (*1)
A
1.9/0.95
Inrush Current(Typical)
-
14A at 100VAC,
28A at 200VAC,
Ta=25
℃
, Cold Start
Power Factor (*1)
-
0.99/0.95
Output Voltage Range
V
9.6~14.4
Maximum Ripple & Noise (*3)
0
≤
Ta
≤
60
℃
mV 150
-10
≤
Ta
≤
0
℃
mV 180
Maximum Line Regulation (*4)
mV 48
Maximum Load Regulation (*5)
mV 96
Temperature Coefficient
-
Less than 0.02%/
℃
Over Current Protection (*6)
A
13.6~
Over Voltage Protection (*7)
V
15.0~17.4
Hold-up Time(Typical) (*8)
-
20ms
Leakage Current (*9)
-
Less than 0.5mA.
0.3mA(Typical) at 100VAC
0.5mA(Typical) at 230VAC
- NOTE -
*1. At 100/200VAC, Ta = 25 and maximum output power.
*2. At 100~240VAC(50/60Hz)
*3. Measure with JEITA RC-9131A probe, Bandwidth of scope: 100MHz.
*4. 85~265VAC, constant load.
*5. No load-Full load, constant input voltage.
*6. Constant current limit and Hiccup with automatic recovery.
Not operate at over load or dead short condition for more than 30sec.
*7. OVP circuit will shutdown output, manual reset (Re power on).
*8. At 100/200VAC, nominal output voltage and maximum output current.
*9. Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz).
D
UDP Co., Ltd.
15