IPX/IPN Series
Installation Guide
01A.01
11
③
Alarm (DO) connection
Only the relay type is supported.
Relay Rating: Max 24VDC 50mA
Caution
!
Do not exceed the maximum relay rating.
Caution
!
Must connect GND port which is located end of the DO terminal block side.
④
LAN connector
This is a 10/100 Base-T Ethernet cable.
Use RJ45 coupler to extend the cable.
⑤
12V DC Power
A 12 DC power connector is required for this device.
12V
Red
Black
DO
COM
Device
Internal
Relay Type
+3.3V
DI
COM
DI
COM
+
-
+
-
Output of
Sensor
Output of
Sensor
Internal
Internal
+
-
Relay Type
Voltage Type