No Zigbee manager software necessary. Please power on the adapters by the following 

procedures with the same PAN ID and Channel no.. 

Step 1: Power on the Coordinator and R1 for pairing and power off the other 

adapters 

Step 2: Power off the Coordinator. Power on the R2 for pairing with R1. Please power 

off the other adapters. 

Step 3: .The rest may be deduced by analogy to the end device. 

If you need to set multi network, please set the different PAN ID, channel no. and short 

address from section 8.3 and 8.5. 

7.3  One by many: Please check the picture of section 2.2. The coordinator will transmit the data to 

the specific devices. The mode will need the short address for data transmission to the 

specific destinations. 

 

Remark: There’re two bytes of data which named the short the address in the Zigbee network 

assigned by the coordinator. You can set with or without the short address, please check 

the section 8.5. 

 

8. Zigbee Manager Software 

8.1  Setting the parameters of the devices for all the roles, coordinator, router and end device. 

Please plug the adapter with the PC via COM port individually. 

8.2  The coordinator will assign the short address to all the routers or end devices when power on 

the adapter. The setting will take effect for the adapters which are in the same PAN ID and 

Channel. 

8.3  If you don’t know the COM port, please check the following procedures. 

Configuration 

 Scan 

 OK 

 Open Port 

If you know the port number, you can get the parameters via the “Test Port” button. 

 

Содержание ZA-L2

Страница 1: ...dBi External Dipole Antenna x 1pc Package Photo White Box Dimension 10 x 5 5 x 5 cm Abbreviation in the label on the box LP Low power C Coordinator R Router D End device 1 Packing Contents 1 1 ZA H5 P...

Страница 2: ...in 9 VCC 5VDC 1 5A Max or external battery 3 3 7 VDC Li Polymer Battery or 3 units standard A AA or AAA battery 3 3 Using the USB cable provided in the package plug the mini USB connector into the Zig...

Страница 3: ...2 4V low MAX 0 5V Output drives capability 20mA Max Voltage 3 3V 3 9 2 Analog Input ADC Max Voltage 3 3V 8bit resolution 3 10RS 232 DB9 connector 3 8 1 Pin out 3 8 2 Signals Pin Signal DTE Direction...

Страница 4: ...Please check the API document 6 2 Zigbee Manager software The software contains the device management RS 232 configuration simple data transmission functions for testing Please check the software on...

Страница 5: ...ces The mode will need the short address for data transmission to the specific destinations Remark There re two bytes of data which named the short the address in the Zigbee network assigned by the co...

Страница 6: ...the adapter after setting and new setting will be available after power on 8 6 Simple test when link successfully Choose one device via the list Window Click the Digital button the green LED which is...

Страница 7: ...all the Zigbee devices in the same Zigbee network Change the role C R D via DIP switch on the top of the adapter Change to role which is different to the existing setting and then power on the adapte...

Страница 8: ...age 30 50 m 500 800 m Tx Power 4 0dBm 16 dBm Rx Sensitivity 97dBm Nominal 90 dBm Nominal Baud Rate Supports 1 2 2 4 4 8 9 6 19 2 38 4 57 6 115 2 230 4 Kbps Connection Point to Multi points UART Interf...