4.2 Example: 

 

Remark: One power line is included in the package. If you need more cable for I/O connector, 

please call. 

 

5. LED Status: 

Status 

Description 

Power LED steadily ON (Red) 

Power ON 

Power LED blinking (Red, 0.5 sec.) 

Low power (Battery) 

Power LED OFF 

Power OFF 

Analog LED steadily ON (Blue) 

Analog Input is available 

Digital LED blinking when transmitting Blue) 

Digital I/O is available 

 

6. Control software 

6.1  API: The adapter is built in the API for the software integration. Please check the API 

document. 

6.2  Zigbee Manager software: The software contains the device management, RS-232 

configuration, simple data transmission functions for testing. Please check the software on 

CD or website. 

7. Transmission mode 

7.1  Broadcast: The coordinator will transmit the data to all the end devices without the routers. 

 

No Zigbee manager software necessary. Just power on the adapters with the same PAN ID 

and Channel no.. If you need to set multi network, please set the different PAN ID, channel no. 

and short address from section 8.3 and 8.5. 

7.2.  One by one via routers without short address: The coordinator will extend the range to the end 

devices. 

 

Digital I/O 

Battery power Input 

Analog Input 

Содержание ZA-L2

Страница 1: ...dBi External Dipole Antenna x 1pc Package Photo White Box Dimension 10 x 5 5 x 5 cm Abbreviation in the label on the box LP Low power C Coordinator R Router D End device 1 Packing Contents 1 1 ZA H5 P...

Страница 2: ...in 9 VCC 5VDC 1 5A Max or external battery 3 3 7 VDC Li Polymer Battery or 3 units standard A AA or AAA battery 3 3 Using the USB cable provided in the package plug the mini USB connector into the Zig...

Страница 3: ...2 4V low MAX 0 5V Output drives capability 20mA Max Voltage 3 3V 3 9 2 Analog Input ADC Max Voltage 3 3V 8bit resolution 3 10RS 232 DB9 connector 3 8 1 Pin out 3 8 2 Signals Pin Signal DTE Direction...

Страница 4: ...Please check the API document 6 2 Zigbee Manager software The software contains the device management RS 232 configuration simple data transmission functions for testing Please check the software on...

Страница 5: ...ces The mode will need the short address for data transmission to the specific destinations Remark There re two bytes of data which named the short the address in the Zigbee network assigned by the co...

Страница 6: ...the adapter after setting and new setting will be available after power on 8 6 Simple test when link successfully Choose one device via the list Window Click the Digital button the green LED which is...

Страница 7: ...all the Zigbee devices in the same Zigbee network Change the role C R D via DIP switch on the top of the adapter Change to role which is different to the existing setting and then power on the adapte...

Страница 8: ...age 30 50 m 500 800 m Tx Power 4 0dBm 16 dBm Rx Sensitivity 97dBm Nominal 90 dBm Nominal Baud Rate Supports 1 2 2 4 4 8 9 6 19 2 38 4 57 6 115 2 230 4 Kbps Connection Point to Multi points UART Interf...

Отзывы: