INSTRUCTIONS FOR USE

The following is the KF4’s initial screen. For accurate splice results, splice mode and heater mode should be 

selected. Basic information about the KF4 is displayed on the initial screen. Check that the proper mode is 

selected before splicing. 

4.1

|  

POWER SUPPLY

The battery pack is built into the battery chamber. Loosen the bottom-cover bolts and exchange the battery. 

Please be cautious when you detach the battery from the chamber. 

4.1.1 BUILT IN BATTERY

4.1.2 BATTERY CHARGING

Before connecting the AC/DC charter’s DC cable to the DC jack of the battery to charge the battery, make sure 

you check the voltage and frequency. When the battery is fully charged, the LED will turn green and power is 

disconnected, activating protection circuit to avoid overcharge. The power is turned back on as the battery 

needs to be charged. Charging resumes when the charger’s DC cable is connected to the battery’s DC jack.

BATTERY STATUS INDICATOR

CURRENT SPLICE MODE

CURRENT HEATER MODE

 

SWIFT KF4-EN, Rev.C                                                                                                                                                                  13 

4.

 

Instructions for Use 

The following is the KF4’s initial screen. For accurate splice results, splice mode and heater mode 
should be selected. Basic information about the KF4 is displayed on the initial screen. Check that 
the proper mode is selected before splicing. 

 

 

 

 

4.1.

 

Power supply   

The battery pack is built into the battery chamber. Loosen the bottom-cover bolts and exchange 
the battery. Please be cautious when you detach the battery from the chamber. 

 

4.1.1  Built-in battery 

 

 

Battery status indicator 

Current splice mode 

Current heater mode 

 

SWIFT KF4-EN, Rev.C                                                                                                                                                                  14 

 

4.1.2  Battery charging 

Before  connecting  the  AC/DC  charter’s  DC  cable  to  the  DC  jack  of  the  battery  to  charge  the 
battery, make sure you check the voltage and frequency. When the battery is fully charged, the 
LED will turn green and power is disconnected, activating protection circuit to avoid overcharge. 
The power is turned back on as the battery needs to be charged; charging resumes when the 
charger’s DC cable is connected to the battery’s DC jack.   

 

 

4.2.

 

How to turn the power on/off   

To power on the KF4, press 

  and hold about 1 second with the wind cover closed. After 

the  functions,  including  motors,  initialize,  the  screen  displays  the  following.  Splice  and  heater 
mode should be selected. The current splice and heater mode are displayed at the bottom of the 
screen. 

 

 

4.2

|  

HOW TO TURN THE POWER ON/OFF

To power on the KF4, press        and hold about 1 second with the wind cover closed. After the functions of

motors and initialize, the screen will display the following. Then splice and heater mode should be selected. 

The current splice and heater mode are displayed at the bottom of the screen. 

4.3

|  

KF4 SLEEVE HEATER 

The sleeve heater of the KF4 reinforces the spliced point of the single fi ber. 

The quality of fusion splicing on the fi ber should be good. 

The fi ber and inserted sleeve tube should be properly aligned and installed on the heater. 

Close the heater cover while the heater is on.  

1

|

 Choose the heater mode after the confi rmation of the length for the sleeve tube when placing a sleeve tube 

on a heater.

2

|

 Place the spliced point in the middle of the sleeve tube fi rst. Then, check the heating part on the heater and 

place the sleeve tube on right position. 

 

SWIFT KF4-EN, Rev.C                                                                                                                                                                  9 

3.

 

Product Outline 

3.1.

 

Function buttons 

BUTTON

 

DESCRIPTION

 

 

Press and hold about 1 second to turn the power on/off.   

 

 

Move the cursor to the left. 

Move fiber to manual mode and adjust the camera’s focus. 
Stripping popup menu should load. 

 

 

Move the cursor to the right. 

Move fiber to manual mode and adjust the camera’s focus. 

 

 

Move the cursor upward.   

Move each motor to manual mode.   

Splice popup menu should load.

 

 

Move the cursor downward. 

Move each motor to manual mode.     

Heater popup menu should load. 

 

 

Initialize the splice function. 

Return to the menu screen.   

 

Complete a selection.   

Follow the next step on the menu screen. 

 

Splice execution. 

 

Return to the initial screen and initialize splice function. 

 

Turn on the heater. 

When it is on, the lamp on the left is in the red.   
Press once more when it is on, and the heater is turned off. 

 

SWIFT KF4-EN, Rev.C                                                                                                                                                                  14 

 

4.1.2  Battery charging 

Before  connecting  the  AC/DC  charter’s  DC  cable  to  the  DC  jack  of  the  battery  to  charge  the 
battery, make sure you check the voltage and frequency. When the battery is fully charged, the 
LED will turn green and power is disconnected, activating protection circuit to avoid overcharge. 
The power is turned back on as the battery needs to be charged; charging resumes when the 
charger’s DC cable is connected to the battery’s DC jack.   

 

 

4.2.

 

How to turn the power on/off   

To power on the KF4, press 

  and hold about 1 second with the wind cover closed. After 

the  functions,  including  motors,  initialize,  the  screen  displays  the  following.  Splice  and  heater 
mode should be selected. The current splice and heater mode are displayed at the bottom of the 
screen. 

 

 

ITEM 

DESCRIPTION

Cable diameter 
Sleeve length 
Heating time 
Temperature range

250µm, 900µm,  2.0mm —  3.0mm

Standard 32mm 

10 — 35 seconds 

130°C — 200 °C

Содержание SWIFT KF4

Страница 1: ...NORTH AMERICA SWIFT KF4 USER MANUAL OPTICAL FIBER ARC FUSION SPLICER Read carefully before running KF4 uclswiftna com...

Страница 2: ...MENU 17 POPUP MENU 19 6 1 SPLICE 22 6 2 HEATER 26 6 3 HISTORY SPLICE RESULT 31 6 4 OPTION 32 6 5 CALIBRATION 35 6 6 ELECTRODES 39 6 7 SETTING 42 6 8 INFORMATION 45 1 2 1 2 3 4 5 6 7 8 9 10 ERROR MESSA...

Страница 3: ...e battery does not completely charge in two hours or when the green LED is not turned on stop charging immediately and contact UCL SWIFT Do not put anything on the AC charger while charging Use only t...

Страница 4: ...CATEGORY SPECIFICATIONS DESCRIPTION Fiber alignment Applicable type of bres Fiber count Applicable ber dimensions Fiber setting and cleaved length Splicing modes Typical splice loss Return loss Splici...

Страница 5: ...mp on the left is in the red Press once more when it is on and the heater is turned off SWIFT KF4 EN Rev C 9 3 Product Outline 3 1 Function buttons BUTTON DESCRIPTION Press and hold about 1 second to...

Страница 6: ...the screen will display the following Then splice and heater mode should be selected The current splice and heater mode are displayed at the bottom of the screen 4 3 KF4 SLEEVE HEATER The sleeve heate...

Страница 7: ...he heater for a sleeve tube may not shrink the sleeve tube properly Especially SOC Splice On Connector should be placed on the right side edge of the heater in order to line up the right end of the sl...

Страница 8: ...at a manhole utility pole etc Work belt components SWIFT KF4 EN Rev C 19 4 7 Use of Work Belt The work belt of Swift KF4 is a type of auxiliary equipment that combines with its main body to facilitate...

Страница 9: ...g quality regular inspection and cleaning are required lens cleaning n on the object lens surface disturbs the identification of fiber core location and causes high splice loss Object lenses should be...

Страница 10: ...nward Move each motor to manual mode Heater popup menu should load Initialize the splice function Return to the menu screen Complete a selection Follow the next step on the menu screen Splice executio...

Страница 11: ...o manual mode an Move the cursor upward Move each motor to manual m Splice popup menu should load Move the cursor downward Move each motor to manual m Heater popup menu should loa Initialize the splic...

Страница 12: ...1 Function buttons BUTTON DESCRIPTION Press and hold about 1 second to turn the power on off Move the cursor to the left Move fiber to manual mode and adjust the camera s focus Stripping popup menu sh...

Страница 13: ...downward Move each motor to manual mode Heater popup menu should load Initialize the splice function Return to the menu screen Complete a selection Follow the next step on the menu screen Splice exec...

Страница 14: ...stopped re arc can also be stopped When re arc is continuously required set as to OFF It sets re arc time Within splice mode edition it automatically sets to arc the re arc amount with the same intens...

Страница 15: ...r plate CAUTIONS SWIFT KF4 EN Rev C 9 3 Product Outline 3 1 Function buttons BUTTON DESCRIPTION Press and hold about 1 second to turn the power on off Move the cursor to the left Move fiber to manual...

Страница 16: ...ice function Return to the menu screen Complete a selection Follow the next step on the menu screen Splice execution Return to the initial screen and initialize splice function Turn on the heater When...

Страница 17: ...result display The splicer can save up to 5 000 splice data and images Each page shows seven splice data and images Use to advance screens 6 3 2 Deletion of splice result Data and images can be delete...

Страница 18: ...n to enter your password The initial password is 1234 TEST ITEM DESCRIPTION Splice lock Heat lock Clear memory lock Password query Restricts modi cation on splice mode Restricts modi cation on heater...

Страница 19: ...utomatically adjusted The central e arc can also be moved toward the left or right In this case arc calibration is required xecuting arc calibration arc voltage is automatically changed to a proper va...

Страница 20: ...to the left Move fiber to manual mode and adjust the camera s focus Stripping popup menu should load Move the cursor to the right Move fiber to manual mode and adjust the camera s focus Move the curs...

Страница 21: ...3 1 Function buttons BUTTON DESCRIPTION Press and hold about 1 second to turn the power on off Move the cursor to the left Move fiber to manual mode and adjust the camera s focus Stripping popup menu...

Страница 22: ...een to select a language is displayed 6 7 2 DATE A screen to set the time and date is displayed SWIFT KF4 EN Rev C 9 Move fiber to manual mode and adjust the camera s focus Move the cursor upward Move...

Страница 23: ...d Move each motor to manual mode Heater popup menu should load Initialize the splice function Return to the menu screen Complete a selection Follow the next step on the menu screen Splice execution Re...

Страница 24: ...umber given to the equipment SWIFT KF4 EN Rev C 9 Move fiber to manual mode and adjust the camera s focus Move the cursor upward Move each motor to manual mode Splice popup menu should load Move the c...

Страница 25: ...rly or there is a foreign substance on the object lens or reflector Solution Press and reposition fiber again Clean the object lens and reflector SWIFT KF4 EN Rev C 9 3 Product Outline 3 1 Function bu...

Страница 26: ...erated when the estimated loss value is higher than the preset loss factor limit SOLUTION Check the loss factor limit 7 6 FIBER THIN ERROR Error message generated when the spliced point becomes thinne...

Страница 27: ...veral completed splices even with the fully charged battery Power is quickly consumed when Save mode is not in use Refer to the Save Mode to assure proper settings If the battery s life ends for long...

Страница 28: ...ns BUTTON DESCRIPTION Press and hold about 1 second to turn the power on off Move the cursor to the left Move fiber to manual mode and adjust the camera s focus Stripping popup menu should load Move t...

Страница 29: ...he product 4 As this product is a high precision device please carry it in the carry case at all times to protect it from humidity vibration and shock CHARGED SERVICE In the following cases a service...

Отзывы: