MENU
ELECTRODE
In normal operation mode, to call the Electrode
menu, press . Then you can see the Electrode
menu as above. It is necessary to regularly check
and clean the electrodes because they are worn
out. The silica oxidized substances is deposited
as the electrodes go through numerous times of
splices. There’re already various functions to
arc count, replace time and other.
MENU
STABILIZE
Sometimes, surrounding environment may cause the
occurrence of irregular arc discharge or splice loss increase.
In particular, since it takes a while until discharge is stabilized
when the splicer is in lower or higher location, you have to keep
adjusting the discharge until the electrodes are stabilized.
Especially after installing new set of electrodes,
he user must do Electrode Stabilize as follows.
� Place the fiber in the arc fusion splicer.
� Click “Stabilize”
� Click .
� Perform �� cycle continuous arc discharge to
stabilize the electrodes.
� Result similar to the picture above is displayed on the
screen when measuring is completed.
� After completing the Electrode Stabilize, ARC
Calibration should be performed separately.
��