SECTION TEN
Checking Operation of Fire
CHECKING GAS SOUNDNESS
Turn on the gas supply to the appliance and check for soundness in accordance with current
codes of practice.
Turn off the gas supply at the external Isolation valve.
Remove the pressure test point screw from the inlet elbow and connect the pressure gauge.
Turn on the gas to the appliance at the Isolation valve.
Push down on the lever to ignition position and allow the air in the pipe to be purged.
Keep the lever down and check that the electrode is sparking at the gap between the
thermocouple tip and the electrode; continue until pilot ignition is established.
When established the control lever may be lifted until a resistance is felt, this will put the burner on
its high setting.
Check that the inlet pressure /- 1 mbar for natural gas or /- 1mbar for propane.
Turn off gas supply, at the isolation valve. Disconnect the pressure gauge and replace the
pressure test point screw.
Turn on the supply to the appliance and check the pressure test point for soundness with
detection fluid.
CONNECTING CONTROL LEVER
Remove the two m4 screws from
the slide bar.
Slide control lever within handle
guide bracket and refit the two
m4 screws.
CONNECTING THE BATTERY
Connect boot lead to battery which is
located on the bottom left hand side of
the appliance.
Slide battery within generator housing
behind retaining clip.