18
LT---- (iss -- --/--)
Taking great care grip the copper protective sleeve
at the end of the gas control spindle (DO NOT GRIP
SPINDLE IN ANY OTHER PLACE) as shown and
remove the screw from the end as shown above.
Ensure the spindle is pushed back inside the
control valve as far as possible. Ensure the bell
crank mechanism is swung up to give easy access
to the gas
connection point as shown.
Cut a cross slit in the rubber grommet and
feed the appliance onto the 8mm-gas supply
pipe. Position the restrictor elbow supplied
and mark supply pipe at its cut off length.
Remove appliance, cut pipe to correct length,
refit appliance and make gas connection with
restrictor elbow use 15mm A/F spanner taking
care not to apply any force to the gas control
spindle as above. Ensure the restrictor valve
is opened
and its cap replaced tightly.
Check for gas soundness. Reconnect the bell
crank mechanism as above ensuring that the gas
control spindle is gripped only over the protective
copper sleeve and no other part of the spindle as,
ensure NO side strain is applied to the spindle.
UC Living Arranmore SC
Installation Instructions
SECTION NINE
To Install the Appliance continued
GLASS PANEL REMOVAL
The trim, which is held in position with magnets.
Remove the fret and ash pan cover.
Lift of the canopy and remove.
Remove the glass fixing clamp secure with three securing
nuts and lift it out of the retaining brackets. Take care to
support the glass panel when removing the fixing clamp. The
glass should be place in a safe place to prevent damage.
Once the fuel bed has been laid reassemble in reverse order.
CONNECTING THE GAS SUPPLY
If it is intended to be a concealed connection the 8mm supply
should be positioned in the opening first.
The pipe should be positioned so that when the appliance is
pushed back into the opening it enters the grommet hole at least
180mm, taking into account the requirements of BS 6891 1988
dealing with enclosed pipes.