UBTECH Sensor-controlled safety sign USER MANUAL
UBTECH ROBOTICS CORP LTD
the disinfection equipment will be informed in time to stop disinfect. After the
disinfection equipment stops disinfect, the status of the equipment will be fed back to
the Sensor-controlled safety sign
•
The disinfection equipment status includes the non safety state of normal operation
of the disinfection equipment, the safe state after the disinfection equipment is shut
down, the non safety state when the disinfection equipment fails, and the state of
disconnection from the disinfection equipment
Indicates the disinfection device status
State
LED
Buzzer
The disinfection equipment is in a
safe state
● ●
:
Green LED long
and bright
/
Disinfection equipment in
disinfection state (unsafe)
●●
:
Blue LED long and
bright
/
Disinfection equipment failure
(unsafe)
●●
:
Red LED long and
bright
Periodic sound, once
every 5 seconds
Lost disinfection device
connection, try to restore
connection
● ●
:
Orange LED long
and bright
Periodic sound, once
every 5 seconds
4.4 Sensor-controlled safety sign State Indicator
In the Bluetooth pairing process between the Sensor-controlled safety sign and the
disinfection device, the status of low power and access control board is indicated:
State
LED
Buzzer
Enter Bluetooth pairing
status
●●:
blue quick flashing
/
Pairing complete
● ●
:
blue goes out and
returns to working state
/
Low battery
Any color light, periodic slow
flashing (3S)
/
Turn on door sensor
detection
/
Three buzzers
Turn off door sensor
detection
/
Buzzer 1 sound
Sensor-controlled safety
sign is touched (under
non security state)
The indicator light remains
unchanged
Make a long sound until the
Sensor-controlled
safety
sign stops moving
4.5 Bluetooth pairing (Web)
As the peripheral equipment of disinfection equipment, the Sensor-controlled safety
sign should be paired through Bluetooth. The [peripheral] tab of [system settings]
provides the pairing of Sensor-controlled safety sign.
•
One disinfection device allows multiple Bluetooth Sensor-controlled safety signs
•
The communication distance of the Sensor-controlled safety sign is not less than 20