LISA-U series - System Integration Manual
UBX-13001118 - R17
Advance information
Appendix
Page 177 of 190
LISA-U1 series
LISA-U2 series
No Name
Description
Name
Description
Remarks for Migration
10
RI
UART ring indicator
output
RI
UART ring indicator
output
Circuit 125 (RI) in ITU-T V.24, 1.8V typ.
LISA-U1 series:
o
Output driver strength = 4 mA
LISA-U2 series:
o
Output driver strength = 2 mA
11
DCD
UART data carrier
detect output
DCD
UART data carrier
detect output
Circuit 109 (DCD) in ITU-T V.24, 1.8V typ.
LISA-U1 series:
o
Output driver strength = 4 mA
LISA-U2 series:
o
Output driver strength = 2 mA
12
DTR
UART data terminal
ready input
DTR
UART data terminal
ready input
Circuit 108/2 (DTR) in ITU-T V. 24, 1.8V typ.
LISA-U1 series:
o
Internal active pull-up = -110 µA
LISA-U2 series:
o
Internal active pull-up = -125 µA
13
RTS
UART ready to send
input
RTS
UART ready to send
input
Circuit 105 (RTS) in ITU-T V.24, 1.8V typ.
LISA-U1 series:
o
Internal active pull-up = -60 µA
LISA-U2 series:
o
Internal active pull-up = -240 µA
14
CTS
UART clear to send
output
CTS
UART clear to send
output
Circuit 106 (CTS) in ITU-T V.24, 1.8V typ.
LISA-U1 series:
o
Output driver strength = 4 mA
LISA-U2 series:
o
Output driver strength = 6 mA
15
TXD
UART transmitted
data input
TXD
UART transmitted
data input
Circuit 103 (TxD) in ITU-T V.24, 1.8V typ.
LISA-U1 series:
o
Internal active pull-up = -60 µA
LISA-U2 series:
o
Internal active pull-up = -240 µA
16
RXD
UART received data
output
RXD
UART received data
output
Circuit 104 (RxD) in ITU-T V.24, 1.8V typ.
LISA-U1 series:
o
Output driver strength = 4 mA
LISA-U2 series:
o
Output driver strength = 6 mA
17
GND
Ground
GND
Ground
18
VUSB_DET
USB detect input
VUSB_DET
USB detect input
No difference:
Input for VBUS (5 V typical) USB supply sense.
19
PWR_ON
Power-on input
PWR_ON
Power-on input
PWR_ON switch-on low pulse time difference:
LISA-U1 series:
o
L-level pulse time = 5 ms min
LISA-U2 series:
o
L-level pulse time = 50 µs min / 80 µs max
PWR_ON switch-off low pulse time difference:
LISA-U1 series:
o
Switch-off by PWR_ON not supported
LISA-U2 series:
o
L-level pulse time = 1 s min
PWR_ON operating voltage difference:
LISA-U1 series:
o
L-level input = -0.30 V min / 0.65 V max
o
H-level input = 2.00 V min / 4.20 V max
o
External pull-up (e.g. to V_BCKP) required
LISA-U2 series:
o
L-level input = -0.30 V min / 0.65 V max
o
H-level input = 1.50 V min / 4.40 V max
o