Ubisys ZIGBEE S2(-R) Скачать руководство пользователя страница 8

8

 

 

www.ubisys.de

 

u

6.

 

MAN-MACHINE INTERFACE (MMI) 

S2 offers a push-button behind a tiny hole in the front-face of the device, as well as a LED right next to 
it

3

. This man-machine interface provides access to a menu. In addition, it provides a handy shortcut to 

factory reset the device

4

To factory reset the device, keep the button pressed for approximately 10 seconds until the LED 
starts to flash. This is equivalent to selecting menu item #5. 

Notice that the device also supports a power-cycle sequencing factory reset as detailed in section 6.1. 

To enter the menu, press and hold the push-button for more than a second until you see three short 
flashes followed by a sequence of one blink, pause, one blink, pause, etc. This indicates that you have 
successfully entered the menu. With each short button press (less than a second), you advance 
through the menu. For example, pressing the button once brings you to the second menu item, which 
S2 indicates by two blinks, pause, two blinks pause, etc. Once you have reached the menu item that 
you want to run, press and hold the button for more than a second to execute the selected item. The 
exact meaning of each menu item depends on the particular device and may vary from firmware version 
to firmware version. 

This is the menu for Power Switch S2 running firmware version 1.03 and above

5

Menu Item # 

Operation 

ZigBee Commissioning: Network Steering 
While in this mode a single press on the button instigates ZigBee Network Steering (“EZ-mode”). If the 
device is on a network it will open the network for new devices for three minutes, otherwise it will attempt to 
join an open network. If the network is already open, the device will close the network instead such that 
repetitive presses toggle the network permit joining state. The LED is on, when the network is open for new 
devices, and off otherwise. 

ZigBee Commissioning: Finding & Binding 
Instigates the ZigBee Finding & Binding procedure (“EZ-mode”) on an initiator or target endpoint. Target 
endpoints will enter identify mode for three minutes. Initiator endpoints will query targets and create suitable 
bindings to these targets. After leaving the menu in this mode, the first button press starts the selection of 
the endpoint and each subsequent press (within half a second) increments the endpoint number. Once the 
desired endpoint is reached, wait for the LED to blink the selected number of times. Then, press a single 
time to accept the selection or wait for three seconds to cancel the command. The LED will blink one time 
to confirm an affirmative choice, or two times to indicate the request has been cancelled. 

ZigBee Commissioning: Clear Bindings 
Clears bindings on an initiator endpoint. Select this menu item and leave menu mode. Afterwards the device 
expects the selection of an initiator endpoint. The first button press starts the selection of the endpoint and 
each subsequent press (within half a second) increments the endpoint number. Once the desired endpoint 
is reached, wait for the LED to blink the selected number of times. Then, press a single time to accept the 
selection or wait for three seconds to cancel the command. The LED will blink one time to confirm an 
affirmative choice, or two times to indicate the request has been cancelled. This mode is active for one 
round only. Afterwards the device reverts to mode #1. 

ZigBee Commissioning: Set Device Role and Factory Reset 
Selects the ZigBee device role for this device on the network, resets the remaining settings to factory 
defaults and restarts the device. Select this menu item and leave menu mode. Afterwards the device 
expects the selection of an option. The first button press starts the selection of the option and each 

 

3

 The high-voltage inputs of S2/S2-R do not count as an MMI feature. 

4

 The 10-second-press factory reset (equivalent to menu item #5) is available since firmware version 1.04. 

5

 Notice: Prior versions have different menu items. Only the factory reset command (menu item #5) is identical 

across all released versions of the firmware. 

Содержание ZIGBEE S2(-R)

Страница 1: ...u ZIGBEE POWER SWITCH S2 R REFERENCE MANUAL...

Страница 2: ...ecific to your region is available as a separate document and is included in printed form in the product package If you have any questions or need additional support please visit the support pages tha...

Страница 3: ...Cluster Server 13 7 2 3 Groups Cluster Server 14 7 2 4 Scenes Cluster Server 14 7 2 5 On off Cluster Server 15 7 3 Application Endpoint 2 On off Output 2 17 7 3 1 Basic Cluster Server 17 7 3 2 Identi...

Страница 4: ...32 Device Management 27 7 7 1 Basic Cluster Server 27 7 7 2 Identify Cluster Client 28 7 7 3 Commissioning Cluster Server 28 7 7 4 Over the Air Upgrade Cluster Client 28 7 7 5 Device Setup Cluster Ser...

Страница 5: ...tralized and distributed security networks as router Supports forming simple centralized security networks as Coordinator and Trust Center Supports forming distributed security networks as router Thre...

Страница 6: ...ng maintenance or early stages of system integration In this mode the ZigBee interface is operational and you can run OTA firmware upgrades for example However the inputs and outputs are non operation...

Страница 7: ...e times slowly to indicate it is operating as a router on the network ten times slowly to indicate that it is operating as a coordinator and trust center or blink quickly to indicate it is searching f...

Страница 8: ...g Binding procedure EZ mode on an initiator or target endpoint Target endpoints will enter identify mode for three minutes Initiator endpoints will query targets and create suitable bindings to these...

Страница 9: ...is reached wait for the LED to blink the selected number of times Then press a single time to accept the selection or wait for three seconds to cancel the command The LED will blink one time to confir...

Страница 10: ...parent for sleeping end devices S2 provides nine ZigBee application endpoints Endpoint Profile Application 0 0x00 0x0000 ZigBee Device Profile ZigBee Device Object ZDO standard management features 1 0...

Страница 11: ...the following example ubisys2 R0 001FEE00000000FF 0F7C1CD805F91649EBA84580AA1CB432F51A 21 Here ubisys2 is the data format identifier R0 is the model string this is just an example it would be S2 or S2...

Страница 12: ...in the network parent_annce parent_annce_rsp14 Parent announcement response This is part of the ZigBee 2015 end device child management feature system_server_discovery_req system_server_discovery_rsp...

Страница 13: ...ssed using the group address This is also a prerequisite for scenes You may also query group membership and delete group associations 0x0005 Inbound Server Scenes Allows storing one or more scenes per...

Страница 14: ...scenes that refer to any of the existing groups 0x05 Add Group if Identifying Adds this endpoint to the group if the endpoint is identifying 7 2 4 Scenes Cluster Server Attributes supported Attribute...

Страница 15: ...g reporting targets Currently there is no default reporting configuration in place so you need to configure reporting if you want to receive feedback on state changes Attributes supported Attribute Ty...

Страница 16: ...ate switching element 0x40 Off with effect19 Turns the output off after having stored the current setting as the global scene and rejects further global scene storage requests by the On with recall gl...

Страница 17: ...ssed using the group address This is also a prerequisite for scenes You may also query group membership and delete group associations 0x0005 Inbound Server Scenes Allows storing one or more scenes per...

Страница 18: ...scenes that refer to any of the existing groups 0x05 Add Group if Identifying Adds this endpoint to the group if the endpoint is identifying 7 3 4 Scenes Cluster Server Attributes supported Attribute...

Страница 19: ...only GlobalSceneControl21 Determines whether the next Off with Effect command will store the global scene 0x4001 unsigned16 read only OnTime21 Time in tenths of a second the device remains on before i...

Страница 20: ...requests by the On with recall global scene command until the device is turned on again or the global scene has been restored 0x41 On with recall global scene21 Restores the global scene Despite the...

Страница 21: ...e is currently identifying and returns the remaining time if so 7 4 3 Scenes Cluster Client This cluster is available on devices running firmware version 1 03 and above Notice This cluster does not us...

Страница 22: ...of devices on 0x02 Toggle Toggles the target device state Should not be used to control groups 7 4 5 Level Control Cluster Client Notice This cluster uses the binding table for managing command target...

Страница 23: ...ce is currently identifying and returns the remaining time if so 7 5 3 Scenes Cluster Client This cluster is available on devices running firmware version 1 03 and above Notice This cluster does not u...

Страница 24: ...of devices on 0x02 Toggle Toggles the target device state Should not be used to control groups 7 5 5 Level Control Cluster Client Notice This cluster uses the binding table for managing command target...

Страница 25: ...ctive power reactive power apparent power RMS voltage RMS current power factor etc 7 6 1 Basic Cluster Server Please refer to section 7 7 1 for details 7 6 2 Metering Cluster Server Notice This cluste...

Страница 26: ...vered positive or generated negative reactive power in VAr 0x0306 unsigned32 read only TotalApparentPower Total of delivered positive or generated negative apparent power in VA 0x0505 unsigned16 read...

Страница 27: ...nd when to install the downloaded image 0xFC00 Inbound Server Device Setup This is a manufacturer specific cluster used for basic device setup For example it can be used to assign physical inputs to e...

Страница 28: ...this endpoint is used for push button commissioning Cluster commands transmitted Command Description 0x01 Query Identify This command is broadcast during push button commissioning to identify suitable...

Страница 29: ...case of S2 this is the white wire Factory default value 0x00 0x0001 Configuration options for high voltage physical input 2 Defines the configuration for the physical input marked with a switch symbol...

Страница 30: ...nstruction shall be executed Field Bit s Description HasAlternate 7 0x80 When this bit is set there is another instruction that shall be executed in alternating order with the current one each time th...

Страница 31: ...the universal input logic unique to ubisys ZigBee devices This can be a simple toggle command or a more complex move or recall scene command for example Notice that S2 and S2 R will use their binding...

Страница 32: ...0006 on off 02 ZCL Command Template Toggle 06 element 2 six bytes 01 InputAndOptions 0x01 0D Transition released pressed 04 Source Endpoint 4 hosts secondary on off client cluster on S2 06 00 Cluster...

Страница 33: ...nidirectional and bidirectional23 GPDs Attributes supported Attribute Type Description 0x0000 unsigned8 read only gpsMaxSinkTableEntries The number of sink table entries supported by this device 0x000...

Страница 34: ...d Description 0x01 GP Pairing Creates updates or removes proxy table entries 0x02 GP Proxy Commissioning Mode Makes the proxy enter commissioning mode for a particular sink or leave commissioning mode...

Страница 35: ...rovides enhanced support for latest generation Green Power generic switches with the ability to distinguish short 1 second and long 1 second presses In fact a generic switch behaves like a physical sw...

Страница 36: ...blocks supported by this device 0x0017 bitmap24 read only gppActiveFunctionality Allows to disable certain Green Power features on this device 0x0020 bitmap8 persistent gpSharedSecurityKeyType Determi...

Страница 37: ...from a Green Power Device to one or more sinks or groups of sinks 0x04 GP Commissioning Notification Tunnels GP frames from a Green Power Device to a sink in commissioning mode 0x0B GP Proxy Table Res...

Страница 38: ...sions Figure 2 Rail mount ZigBee Dual Power Switch S2 R Dimensions Funkvernetzt mit Stromverbrauchsmessung Leistungsschalter S2 230 V 50 Hz 2 x 500 VA 2 1 2 1 43 mm 12 mm 143 mm 47 mm 12 mm Funkvernet...

Страница 39: ...ilable Use the specified order code for your orders Please contact ubisys support if you require any customization Order Code Description 1069 ZigBee Dual Power Switch S2 in wall flush mount 1168 ZigB...

Страница 40: ...ERMS CONDITIONS OF BUSINESS When placing your order you agree to be bound by our General Terms Conditions of Business Allgemeine Gesch ftsbedingungen which are available for download here http www ubi...

Страница 41: ...MC 2014 35 EU Low Voltage Directive LVD 2012 19 EU Waste Electrical and Electronic Equipment Directive WEEE 2011 65 EU Restriction of Hazardous Substances Directive RoHS EN 300 328 V2 2 2 ERM Wideband...

Страница 42: ...ry reset it will broadcast a network leave indication 1 5 11 11 2015 Updated the ZDO description to include enhancements and additions made for ZigBee 2015 platform compliance 1 6 11 19 2015 Enhanceme...

Страница 43: ...43 www ubisys de u 13 CONTACT UBISYS TECHNOLOGIES GMBH NEUMANNSTRASSE 10 40235 D SSELDORF GERMANY T 49 211 54 21 55 00 F 49 211 54 21 55 99 www ubisys de info ubisys de...

Отзывы: