7.6.3.
Electrical Measurement Cluster (Server)
Notice: This cluster uses the binding table for managing reporting targets. Currently, there is no default
reporting configuration in place, so you need to configure reporting, if you want to receive feedback on
state changes.
Attributes supported:
Attribute
Type
Description
0x0000
bitmap32,
read-only
MeasurementType
Indicates the physical entities that this devices is able to measure.
0x0300
unsigned16,
read-only
Frequency
The frequency of the measured AC voltage (sine wave), in 0.001 Hz.
0x0304
signed32,
read-only
TotalActivePower
Total of delivered (positive) or generated (negative) active power, in W.
0x0305
signed32,
read-only
TotalReactivePower
Total of delivered (positive) or generated (negative) reactive power, in VAr.
0x0306
unsigned32,
read-only
TotalApparentPower
Total of delivered (positive) or generated (negative) apparent power, in VA.
0x0505
unsigned16,
read-only
RMSVoltage (L1)
Phase L1: RMS voltage.
0x0508
unsigned16,
read-only
RMSCurrent (L1)
Phase L1: RMS current.
0x050B
signed16,
read-only
ActivePower (L1)
Phase L1: Delivered (positive) or generated (negative) active power, in W.
0x050E
signed16,
read-only
ReactivePower (L1)
Phase L1: Delivered (positive) or generated (negative) reactive power, in VAr.
0x050F
unsigned16,
read-only
ApparentPower (L1)
Phase L1: Delivered (positive) or generated (negative) apparent power, in VA.
0x0510
signed8,
read-only
Powerfactor (L1)
Phase L1: Power factor of the attached load, in 0.01 units. Positive values indicate an
inductive load (L), negative values a capacitive load (C), close to zero values a resistive
load (R) and close to 1.00 purely capacitive/inductive loads.