u

7.3.

 

Application Endpoint #2 (S1/S1-R) – Primary Level Control Switch 

This is a Finding & Binding initiator endpoint. 

7.3.1.

 

Basic Cluster (Server) 

Please refer to section 7.7.1 for details. 

7.3.2.

 

Identify Cluster (Server) 

Notice: The identify cluster instance on this endpoint does not provide any visual or audible feedback. It 
is mainly present to comply with standards requirements. 

Attributes supported: 

Attribute 

Type 

Description 

0x0000 

unsigned16 

IdentifyTime 
The remaining time, in seconds, the device will be identifying itself. 
Notice that S1 currently does not provide any visual feedback in identify mode. 

 

Cluster commands supported: 

Command 

Description 

0x00 

Identify 
Puts the device into identify mode, or terminates identify mode. 

0x01 

Query Identify 
Determines whether the device is currently identifying, and returns the remaining time if so. 

7.3.3.

 

Scenes Cluster (Client) 

This cluster is available on devices running firmware version 1.04 and above. 

Notice: This cluster does not use the binding table for managing command targets. Instead, recall 
scene command templates include the group address and scene number to recall. The device setup 
cluster on the Device Management endpoint can be used to configure the behavior of the cluster, i.e. 
which identifiers will be sent in the message body, when the input state changes. Using the device 
setup cluster, you can configure this endpoint either to be used with a push-button or a switch. 

This cluster instance is intended for recalling scenes on the local and/or remote devices using the local 
inputs and is not bound when factory fresh. 

Cluster commands transmitted: 

Command 

Description 

0x05 

Recall Scene 
Recalls a scene. The group address in the recall scene command payload is also used as the target for the 
command. 

Содержание S1

Страница 1: ...u ZIGBEE POWER SWITCH S1 R REFERENCE MANUAL...

Страница 2: ...ation guide specific to your region is available as a separate document and is included in printed form in the product package If you have any questions or need additional support please visit the sup...

Страница 3: ...luster Server 14 7 2 3 Groups Cluster Server 15 7 2 4 Scenes Cluster Server 15 7 2 5 On off Cluster Server 16 7 3 Application Endpoint 2 S1 S1 R Primary Level Control Switch 18 7 3 1 Basic Cluster Ser...

Страница 4: ...ent 25 7 7 3 Commissioning Cluster Server 25 7 7 4 Over the Air Upgrade Cluster Client 25 7 7 5 Device Setup Cluster Server 25 7 8 Application Endpoint 242 ZigBee Green Power 30 7 8 1 Green Power Clus...

Страница 5: ...12 13 14 16 17 18 19 21 22 23 24 26 Supports joining centralized and distributed security networks as router Supports forming simple centralized security networks as Coordinator and Trust Center Suppo...

Страница 6: ...ring maintenance or early stages of system integration In this mode the ZigBee interface is operational and you can run OTA firmware upgrades for example However the inputs and outputs are non operati...

Страница 7: ...e times slowly to indicate it is operating as a router on the network ten times slowly to indicate that it is operating as a coordinator and trust center or blink quickly to indicate it is searching f...

Страница 8: ...g Binding procedure EZ mode on an initiator or target endpoint Target endpoints will enter identify mode for three minutes Initiator endpoints will query targets and create suitable bindings to these...

Страница 9: ...is reached wait for the LED to blink the selected number of times Then press a single time to accept the selection or wait for three seconds to cancel the command The LED will blink one time to confir...

Страница 10: ...eshing capabilities as well as serving as a connection point parent for sleeping end devices Due to the additional input on S1 R the anatomy of S1 and S1 R is slightly different S1 provides seven ZigB...

Страница 11: ...manufacturer code is used to identify OTA upgrade images for accessing manufacturer specific ZCL attributes and commands etc Installation Code This power switch has a pre configured link key which is...

Страница 12: ...0 00 1F EE 00 00 00 00 FF 0F 7C 1C D8 05 F9 16 49 EB A8 45 80 AA 1C B4 32 F5 1A 21 Notice The data format ubisys1 is identical to ubisys2 except for the check sum which is present but invalid If you...

Страница 13: ...vice in the network parent_annce parent_annce_rsp19 Parent announcement response This is part of the ZigBee 2015 end device child management feature system_server_discovery_req system_server_discovery...

Страница 14: ...dressed using the group address This is also a prerequisite for scenes You may also query group membership and delete group associations 0x0005 Inbound Server Scenes Allows storing one or more scenes...

Страница 15: ...scenes that refer to any of the existing groups 0x05 Add Group if Identifying Adds this endpoint to the group if the endpoint is identifying 7 2 4 Scenes Cluster Server Attributes supported Attribute...

Страница 16: ...Notice This cluster uses the binding table for managing reporting targets Currently there is no default reporting configuration in place so you need to configure reporting if you want to receive feed...

Страница 17: ...e global scene and rejects further global scene storage requests by the On with recall global scene command until the device is turned on again or the global scene has been restored 0x41 On with recal...

Страница 18: ...evice is currently identifying and returns the remaining time if so 7 3 3 Scenes Cluster Client This cluster is available on devices running firmware version 1 04 and above Notice This cluster does no...

Страница 19: ...arget device state Should not be used to control groups 7 3 5 Level Control Cluster Client This cluster is available on devices running firmware version 1 04 and above Notice This cluster uses the bin...

Страница 20: ...uery Identify Determines whether the device is currently identifying and returns the remaining time if so 7 4 3 Scenes Cluster Client Notice This cluster does not use the binding table for managing co...

Страница 21: ...be used to control groups 7 4 5 Level Control Cluster Client Notice This cluster uses the binding table for managing command targets In addition the device setup cluster on the Device Management endp...

Страница 22: ...mation regarding energy and power 0x0B04 Inbound Server Electrical Measurement Provides electrical measurement figures for example line frequency active power reactive power apparent power RMS voltage...

Страница 23: ...erated negative active power in W 0x0305 signed32 read only TotalReactivePower Total of delivered positive or generated negative reactive power in VAr 0x0306 unsigned32 read only TotalApparentPower To...

Страница 24: ...te and when to install the downloaded image 0xFC00 Inbound Server Device Setup This is a manufacturer specific cluster used for basic device setup For example it can be used to assign physical inputs...

Страница 25: ...this endpoint is used for push button commissioning Cluster commands transmitted Command Description 0x01 Query Identify This command is broadcast during push button commissioning to identify suitable...

Страница 26: ...the physical input marked with a switch symbol and using the white cable Factory default value 0x00 For S1 R this relation is as follows Element Description 0x0000 Configuration options for high volta...

Страница 27: ...s field contains the physical input number in the lower four bits and indexes into the InputConfigurations array For example a value of 0 identifies the first physical input All other bits are reserve...

Страница 28: ...nd frame The cluster ID must be an operational cluster according to ZCL definitions CommandTemplate This is the template of a ZCL command frame payload which will be sent to the target device once the...

Страница 29: ...hich is aimed at push buttons momentary one stable position 41 element type 0x41 raw data 02 00 element count 0x0002 2 entries 06 element 1 six bytes 00 InputAndOptions 0x00 0D Transition released pre...

Страница 30: ...nidirectional and bidirectional26 GPDs Attributes supported Attribute Type Description 0x0000 unsigned8 read only gpsMaxSinkTableEntries The number of sink table entries supported by this device 0x000...

Страница 31: ...mmand Description 0x01 GP Pairing Creates updates or removes proxy table entries 0x02 GP Proxy Commissioning Mode Makes the proxy enter commissioning mode for a particular sink or leave commissioning...

Страница 32: ...es with the ability to distinguish short 1 second and long 1 second presses In fact a generic switch behaves like a physical switch directly connected to the high voltage input lines resulting in a co...

Страница 33: ...blocks supported by this device 0x0017 bitmap24 read only gppActiveFunctionality Allows to disable certain Green Power features on this device 0x0020 bitmap8 persistent gpSharedSecurityKeyType Determi...

Страница 34: ...from a Green Power Device to one or more sinks or groups of sinks 0x04 GP Commissioning Notification Tunnels GP frames from a Green Power Device to a sink in commissioning mode 0x0B GP Proxy Table Res...

Страница 35: ...Dimensions Figure 2 Rail mount ZigBee Power Switch S1 R Dimensions Leistungsschalter S1 Funkvernetzt mit Stromverbrauchsmessung 230 V 50 Hz 3 680 VA 43 mm 12 mm 143 mm 47 mm 17 mm Funkvernetzt mit St...

Страница 36: ...s available Use the specified order code for your orders Please contact ubisys support if you require any customization Order Code Description 1052 ZigBee Power Switch S1 in wall flush mount 1151 ZigB...

Страница 37: ...ERMS CONDITIONS OF BUSINESS When placing your order you agree to be bound by our General Terms Conditions of Business Allgemeine Gesch ftsbedingungen which are available for download here http www ubi...

Страница 38: ...2014 35 EU Low Voltage Directive LVD 2012 19 EU Waste Electrical and Electronic Equipment Directive WEEE 2011 65 EU Restriction of Hazardous Substances Directive RoHS EN 300 328 V2 2 2 ERM Wideband t...

Страница 39: ...02 2015 Starting with firmware revision 1 06 when the device is factory reset it will broadcast a network leave indication 1 6 11 11 2015 Updated the ZDO description to include enhancements and additi...

Страница 40: ...40 www ubisys de u 13 CONTACT UBISYS TECHNOLOGIES GMBH NEUMANNSTRASSE 10 40235 D SSELDORF GERMANY T 49 211 54 21 55 00 F 49 211 54 21 55 99 www ubisys de info ubisys de...

Отзывы: