Introduction

Thank you for purchasing the Ubiquiti Networks® UniFi® LED 
Panel. This Quick Start Guide is designed to guide you through 
installation and includes warranty terms.

Package Contents

LED

Network-Managed  

LED Panel Powered by PoE+

Model: ULED-AT

UniFi LED Panel

Quick Start Guide

System Requirements

•  An 802.3at-compliant network switch
•  UniFi LED mobile app software

•  Mobile device: iOS 10 or Android 5.0

•  UniFi LED Controller software

•  Computer: UniFi Application Server (UAS) 0.5.0,  

Ubuntu 16.04 LTS (Xenial Xerus) 64-bit or Debian 9 64-bit

•  Web browser: Google Chrome (Other browsers may have 

limited functionality.)

•  UniFi Dimmer Switch, model UDIM-AT or UDIM-AC

Содержание UniFi LED ULED-AT

Страница 1: ...LED Network Managed LED Panel Powered by PoE Model ULED AT ...

Страница 2: ...ed by PoE Model ULED AT UniFi LED Panel Quick Start Guide System Requirements An 802 3at compliant network switch UniFi LED mobile app software Mobile device iOS 10 or Android 5 0 UniFi LED Controller software Computer UniFi Application Server UAS 0 5 0 Ubuntu 16 04 LTS Xenial Xerus 64 bit or Debian 9 64 bit Web browser Google Chrome Other browsers may have limited functionality UniFi Dimmer Switc...

Страница 3: ... local user runs the app to connect to a UniFi AP on the same Layer 2 network as the UniFi LED Panel UniFi LED Controller over Layer 2 Network A local user runs the LED Controller software on the same Layer 2 network as the UniFi LED Panel UniFi PoE Switch Internet LAN WAN UAP AC PRO 802 3at PoE ULED AT UniFi Application Server UniFi LED Controller UDIM AT UniFi LED App 802 3af PoE USG PRO 4 DHCP ...

Страница 4: ...mer Switch only A UniFi Dimmer Switch connected to the same Layer 2 network as the UniFi LED Panel For LED Controller software A UniFi Application Server running the UniFi LED Controller software and connected to the same Layer 2 network as the UniFi LED Panel For UniFi LED app only A UniFi AP connected to the same Layer 2 network as the UniFi LED Panel ...

Страница 5: ...Hardware Overview Status LED LED LED Color Status Flashing White Initializing Steady White System ready Steady Blue Adopted by LED Controller Alternating White Blue Firmware upgrade is taking place ...

Страница 6: ...ith 802 3at PoE Note The PoE port requires 25W of power which can be supplied by an 802 3at compliant UniFi Switch MAC Sticker Used to scan the MAC address For details refer to Quick Setup Button Reset The Reset button serves two functions Restart Press and release the Reset button quickly Restore to Factory Default Settings Press and hold the Reset button for more than five seconds ...

Страница 7: ...anel 1 Connect one end of an Ethernet cable to the PoE port on the back of the UniFi LED Panel 2 Connect the other end of the cable to an 802 3at compliant switch port that can provide 25W PoE 3 Lift the panel and seat it in an opening in the ceiling grid ...

Страница 8: ...for the software you wish to use UniFi LED App 1 Install the UniFi LED app on your smartphone or mobile device The app is available from the App Store or Google Play Store 2 Launch the app 3 Follow the on screen instructions to configure the UniFi LED Panel ...

Страница 9: ...are from www ubnt com download unifi led UAS users Install the software using the UAS management console 2 Launch a web browser and go to https localhost 20443 3 The UniFi LED Controller will appear allowing you to configure the UniFi LED Panel as well as customize other settings For additional details on the UniFi LED Controller refer to the documentation at www ubnt com download unifi led ...

Страница 10: ...sed to scan the device s MAC address The Quick Setup consists of these steps Create the QR Code Log Install the LED Panels and Dimmer Switches Scan the QR codes Create the QR Code Log 1 Download the QR Code Log template at ubnt link QR Code Log 2 Print out as many copies as needed each sheet can log up to 16 LED Panels and 3 Dimmer Switches Site Controller QR Code Log UDIM AT XXXXXX arrows and pla...

Страница 11: ... tab OR 2 Place the sticker on the QR Code Log sheet that matches the device s location Site Controller QR Code Log UDIM AT XXXXXX arrows and place them on this QR Code Log ULED AT XXXXXX OR Site Controller QR Code Log UDIM AT XXXXXX arrows and place them on this QR Code Log UDIM AT XXXXXX 3 Install the device as decribed in the Installation section of the device s Quick Start Guide ...

Страница 12: ...ns as the UniFi LED app guides you through the process of adding devices by scanning the QR codes on the QR Code Log sheet s Note Instead of scanning the QR codes you can also use the UniFi LED app s Locate function to identify and assign individual LED Panels to their groups however this is best suited for smaller installations ...

Страница 13: ...hod 802 3at PoE Supported Voltage Range Standard PoE 42 5 57 0V Max Power Consumption 25 5W Mounting Standard T Grid Operating Temperature 0 to 40 C 32 to 104 F Certifications FCC IC Lighting Initial Delivered Luminance Max 2300 lm Efficacy 100 lm W CCT 4 000 K L80 50 000 hrs CRI 80 Beam Angle 114 Brightness Control 10 100 Dimming Environment Indoor Dry Location Based on power delivered to the LED...

Страница 14: ... voltage frequency and current requirements indicated on the manufacturer s label Connection to a different power source than those specified may result in improper operation damage to the equipment or pose a fire hazard if the limitations are not followed 2 There are no operator serviceable parts inside this equipment Service should be provided only by a qualified service technician Limited Warra...

Страница 15: ...communications Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This radio transmitter FCC ID SWX ULEDAT has been approved by FCC ISED Canada CAN ICES 3 A NMB 3 A This device complies with ISED Canada licence exempt RSS standard s Operation is subject to the following tw...

Страница 16: ...property of their respective owners AIJL031819 IMPORTANT NOTE Radiation Exposure Statement This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator your body This transmitter must not be co located or operating in conjunction with any other antenna or ...