Installation Requirements
Clear line of sight between airFiber AP and station
Clear view of the sky for proper GPS operation
Vertical mounting orientation
Mounting point:
At least 1 m below the highest point on the structure
For tower installations, at least 3 m below the top of the tower
Outdoor, shielded Category 6 (or above) cabling and shielded RJ45 connectors are required for all wired Ethernet
connections.
Surge protection should be used for all outdoor installations. We recommend that you use two Ethernet Surge Protectors,
model ETH-SP-G2, one near the airFiber radio and the other at the entry point to the building. The ETH-SP-G2 will absorb
power surges and safely discharge them into the ground.
Note:
For guidelines about grounding and lightning protection, follow your local electrical regulatory codes.