4. 

Slave

  Aim the Slave at the Master to achieve the strongest 

signal level on the Master.

Note:

 Refer to the Signal LEDs section for details on 

the signal values.

Note:

 Maximum signal strength can best be 

achieved by iteratively sweeping through both 
azimuth and elevation.

5. 

Master

  Aim the Master at the Slave to achieve the 

strongest signal level on the Slave.

6.  Repeat steps 4 and 5 until you achieve an optimal link, with 

all four Signal LEDs solidly lit. This ensures the best possible 
data rate between the airFiber radios.

7.  Lock the alignment on both airFiber antennas by 

tightening all the nuts and bolts.

8.  Observe the Signal LEDs of each airFiber radio to ensure 

that the values remain constant while tightening the nuts 
and bolts. If any LED value changes during the locking 
process, loosen the nuts and bolts, finalize the alignment 
of each airFiber antenna again, and retighten the nuts 
and bolts.

Содержание AF-3X

Страница 1: ...3 GHz Carrier Backhaul Radio Model AF 3X DATA MGMT GPS LINK DATA MGMT GPS LINK...

Страница 2: ...Contents DATA MGMT GPS LINK airFiber AF 3X GPS Antenna Mount External GPS Antenna Metal Strap 3 GHz Carrier Backhaul Radio Model AF 3X DATA MGMT GPS LINK DATA MGMT GPS LINK Cable Ties Qty 2 airFiber...

Страница 3: ...t least 3 m below the top of the tower Ground wires min 10 AWG 5 mm2 and max length 1 m As a safety precaution ground the airFiber radio to grounded masts poles towers or grounding bars WARNING Failur...

Страница 4: ...Hardware Overview DATA MGMT GPS LINK Port Cover LED Panel Connects to External GPS Antenna Chain 1 Connects to 45 on airFiber Antenna Chain 0 Connects to 45 on airFiber Antenna...

Страница 5: ...iber Configuration Interface When In Band Management is disabled the MGMT port is the only port that can monitor configure and or update firmware Reset Button To reset to factory defaults press and ho...

Страница 6: ...Hz flash This continues until the AF 3X is fully booted Signal Level Once fully booted the Signal 1 4 LEDs act as a bar graph showing how close the AF 3X is to ideal aiming This is auto scaled based o...

Страница 7: ...Normal Flash Non Operational Weak Signal On Operational Strong Signal MGMT Off No Ethernet Link On Ethernet Link Established Random Flashing Ethernet Activity DATA Off No Ethernet Link On Ethernet Lin...

Страница 8: ...t and connect your computer to the MGMT port Configure the AF 3X Install a ground wire and mount the AF 3X on an airFiber X antenna At the installation site install the airFiber X antenna with the mou...

Страница 9: ...rt labeled POE on the airFiber PoE Adapter WARNING Use only the included airFiber PoE Adapter Model GP H240 100G 4 Failure to do so can damage the unit and void the product warranty 4 Connect the Powe...

Страница 10: ...and the other as the Slave Frequency Setting The operating Frequency must be the same on both the Master and the Slave 1 Connect an Ethernet cable from your computer to the MGMT port on the AF 3X 2 Co...

Страница 11: ...untry Code to ensure compliance with FCC regulations 5 The Main tab will appear Click the Tools drop down and select Link Calculator This tool will guide you on how to best minimize bandwidth and powe...

Страница 12: ...tings 9 Configure the Frequency Setting The selected Frequency must be the same on both airFiber radios 10 Configure the Wireless Security a Select the AES Key Type HEX or ASCII b For the Key field HE...

Страница 13: ...ddress option DHCP Keep the default DHCP to use DHCP reservation on your router to assign a unique IP Address Static Change the IP Address Netmask and other settings to make them compatible with your...

Страница 14: ...AWG or 5 mm2 to the lug and replace the nut to secure the wire 3 At the installation site secure the other end of the ground wire to a grounded mast pole tower or grounding bar WARNING Failure to pro...

Страница 15: ...Mount to the airFiber X Antenna 1 Attach the AF 3X to the mounting bracket a Align the mounting tabs on the back of the AF 3X with the mounting bracket b Slide the AF 3X down to lock it into place...

Страница 16: ...3X in this combination 45 to Chain 0 and 45 to Chain 1 3 Attach the External GPS Antenna to the RF connector labeled GPS Then place the magnetic External GPS Antenna on the bracket this is temporary y...

Страница 17: ...4 Attach the protective shroud a Align the hash mark on the top of the shroud with the notch on the dish antenna b Rotate the shroud clockwise until it locks into place...

Страница 18: ...and as far away as possible from the AF 3X 1 Attach the GPS Antenna Mount to the pole using the metal strap or attach it to a wall using the appropriate fasteners not included 2 Place the External GP...

Страница 19: ...Connecting Power over Ethernet 1 Lift the release latch on the bottom of the AF 3X and slide the Port Cover off 2 Connect an outdoor shielded Ethernet cable to the DATA port...

Страница 20: ...airFiber PoE Adapter Model GP H240 100G 4 Failure to do so can damage the unit and void the product warranty 4 Connect an Ethernet cable from your network to the Ethernet port labeled LAN on the airF...

Страница 21: ...Place the Mounting Bracket at the desired location and mark the holes for the fasteners Pre drill the holes if necessary then secure the bracket to the wall using two fasteners not included 3 Attach...

Страница 22: ...stall the first surge protector within one meter of the airFiber DATA port and install the second surge protector at the ingress point of the location housing the wired network equipment Ground to Pol...

Страница 23: ...elevation differences between airFiber radios Establishing a Link Adjust the positions of the Master and the Slave to establish a link Note The Master must be aimed first at the Slave because the Slav...

Страница 24: ...ve at the Master To adjust the Slave s position a Loosen the four pole clamp nuts and rotate the airFiber antenna on the pole to align the azimuth b Loosen the six elevation bolts and use the hex nut...

Страница 25: ...e Slave 6 Repeat steps 4 and 5 until you achieve an optimal link with all four Signal LEDs solidly lit This ensures the best possible data rate between the airFiber radios 7 Lock the alignment on both...

Страница 26: ...it is the professional installer s responsibility to make sure the device is operated within local country regulatory requirements The Output Power Antenna Gain Cable Loss and Frequency fields are pro...

Страница 27: ...90 Z CE EN 302 217 2 2 Operating Temperature 40 to 55 C 40 to 131 F Networking Interface Data Port 1 10 100 1000 Ethernet Port Management Port 1 10 100 Ethernet Port System Maximum Throughput 500 Mbp...

Страница 28: ...orks Inc All rights reserved Ubiquiti Ubiquiti Networks the Ubiquiti U logo the Ubiquiti beam logo airFiber airOS Rocket and TOUGHCable are trademarks or registered trademarks of Ubiquiti Networks Inc...

Отзывы: