Installing the UbiCell
For a more detailed demonstration of
UbiCell installation, watch the
STEP 1 Check NEMA Receptacle
Check that all contacts on the NEMA
receptacle are clean. Check that the
NEMA receptacle does not rotate. If
the receptacle rotates, ensure it is
locked in place before installing.
NOTE: If the receptacle cannot be
locked in place, then it must be held in
place during UbiCell installation.
STEP 2 NEMA Connector Options
Decide which NEMA option diagram
is applicable to the unit and install.
NOTE: See page 6 for NEMA connector
options.
STEP 3 Install the UbiCell
Insert the UbiCell into the NEMA
socket and
apply downward
pressure
while turning
clockwise
about 15 degrees
until rotation
completely stops.
NOTE: Optimal communication can be
achieved with a 10ft / 3m minimum
obstruction clearance around the
device.
NOTE: Watch the
preparing the NEMA receptacle for
installation.
~
10 lbs
~ 15°