7. Liquid Propane Hook-Up
Attach the regulator to the propane cylinder by
turning the regulator handle clockwise .
When the outdoor cooking appliance is
not being, the gas must be turned “OFF” at the
propane cylinder.
Check all gas supply fittings for leaks before
each use. Do not use the grill until all connections
have been checked and do not leak
(see “Leak Testing” instructions on page 14).
INSTALLATION INSTRUCTIONS
GAS HOOK-UP
Only the pressure regulator and hose assembly supplied with the grill should be used. Any replacement
pressure regulator and hose assembly must be provided by the grill manufacturer.
This grill is configured for Liquid Propane only. Do not use a Natural Gas supply.
Total gas consumption (per hour) with all burners set on “HIGH”:
Main burners 14,000 BTU/Hr
U-shape burner 13,500 BTU/Hr
Side burner 12,000 BTU/Hr
Rear burner 10,000 BTU/Hr
Total
77,500 BTU/Hr.
The installation of this appliance must comply with local codes or, in the absence of local codes, with
either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, National Gas Propane Installation Code, CSA
B149.2.
Installation in Canada must be in accordance with the Standard CAN/CGA-B149.2 (installation code for
gas burning appliances and equipment) and local codes.
LIQUID PROPANE CYLINDER REQUIREMENTS
(20-lb. Cylinder)
A dented or rusty propane cylinder may be hazardous and should be checked by your supplier. Never
use a cylinder with a damaged valve. The propane cylinder must be constructed and marked in
accordance with propane cylinder specifications by the National Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres and Tubes for Transportation of Dangerous Goods Commission.
The 20-lb. cylinder must have a shut-off valve terminating in a valve outlet specified, as applicable, for
connection type QCC1 in the standard for compressed gas cylinder valve outlet and inlet connection
ANSI/CGA-V-1.
Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance. The cylinder system must be arranged for vapour
withdrawal. The cylinder must include a collar to protect the cylinder valve.
Manifold pressure: (operating) 10 inches water column (W.C.), (non-operating) 11.2 inches water column
(W.C.).
Propane Cylinder
Regulator
Fig. 9
Always keep the LP cylinder at
90° (upright) orientation to
provide vapour withdrawal.