Manifold pressure: (operating) 10 inches water column (W.C.), (non-operating) 11.2 inches water column
(W.C.).
Liquid Propane Cylinders must be provided with a listed overfilling prevention device.
Remove the plastic valve cover from the Liquid Propane Cylinder. Make sure the grill gas hoses do not
contact the grease pan or grill body when the Liquid Propane Cylinder is placed into the cart.
CONNECTING THE LIQUID PROPANE CYLINDER
To connect the Liquid Propane Gas Supply Cylinder:
a) The cylinder valve should be in the “OFF” position. If not, turn the valve
clockwise until it stops.
b) Make sure the cylinder valve has the proper type-1 external male thread
connections per ANSI Z21.81.
c) Make sure the burner valves are in the “OFF” position.
d) Inspect the valve connections, port and regulator assembly. Remove debris and inspect the hose
for damage.
e) When connecting the regulator assembly to the valve, use your hand to tighten the nut clockwise
until it stops. Use of a wrench could damage the quick coupling nut and result in a hazardous
situation.
f) Open the cylinder valve fully by turning the valve counterclockwise.
g) Before lighting the grill, use a soap and water solution to check all the connections for leaks.
h) If a leak is found, turn the cylinder valve “OFF” and do not use the grill until a local Liquid Propane
dealer can make repairs.
WARNING
Never attempt to use damaged or obstructed equipment. See your local Liquid Propane dealer for repair.
DISCONNECTING THE LIQUID PROPANE CYLINDER
1. Turn the grill burner valves “OFF” and make sure the grill is cool.
2. Turn the Liquid Propane Cylinder valve “OFF” by turning clockwise until it stops.
3. Detach the regulator assembly from the cylinder valve by turning the quick coupling nut
counterclockwise.
4. Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of
dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or
plugs may result in leakage of propane.
LEAK TESTING
GENERAL
Although gas connections on the grill are leak tested prior to shipment, a complete leak test must be
performed at the installation site. Before each use, check all gas connections for leaks using the
procedures listed below.
If the smell of gas is detected at any time, you should immediately check the entire system for leaks.
Please make sure the cylinder valve connection device
properly and safely mates with the connection device
attached to the inlet of the pressure regulator.