17
OPERATION INSTRUCTIONS
Shut Down:
1. Turn control knob clockwise to PILOT. (Normally, burner will make a slight popping sound when
extinguished.) Burner will extinguish but PILOT will remain ON.
2. To extinguish PILOT, depress control knob and continue to turn it clockwise to OFF.
3. Turn cylinder valve clockwise to OFF and disconnect regulator when heater is not in use.
Note:
After use, some discoloration of the emitter screen is normal.
Operation Checklist
For a safe and pleasurable heating experience, perform this check before each use.
Before Operating:
1. User is familiar with entire owner’s manual and understand all precautions noted.
2. All components are properly assembled, intact and operable.
3. No alterations have been made.
4. All gas connections are secure and do not leak.
5. Outside temperature is adequate. Please note that wind velocity is below 10 mph.
6. Unit will operate at reduced efficiency below 40°F.
7. Heater is outdoors (outside any enclosure).
8. There is adequate fresh air ventilation.
When heater is ON:
The flame should be blue with straight yellow tops. If excessive yellow flame is detected, turn off
heater and consult “Troubleshooting” on page 19.
Re-lighting:
Note:
For your safety, control knob cannot be turned OFF without first
depressing control knob in PILOT position and then rotating it to OFF.
1. Turn control knob to OFF.
2. Wait at least 5 minutes, to let gas dissipate, before attempting to relight pilot light. Failure to follow
this warning could cause a flash ignition or explosion.
3. Repeat the “Lighting” steps on prior page.
WARNING
FOR YOUR SAFETY
Be careful when attempting to manually ignite this
heater. Holding in the control knob for more than 20
seconds before igniting the gas will cause a ball of
flame upon ignition.
WARNING
FOR YOUR SAFETY
Heater will be hot after use. Do not touch or move
the heater until it is completely cooled (approx. 45
minutes).