Pin 41 is shown as example for output on GPS Out 3. Pins 54, 56 or 58 can be used as alternates.
After wiring is complete configure the GNS to send ADS-B+ to Echo as follows:
Power on the GNS and press and hold the ENT key and turn the unit on. Release the
ENT key when the display activates. After the GNS has completed startup you can
access the port configuration using the right-hand knob.
Configuration pages can be accessed by ensuring the cursor is off and rotating the
small right knob.
To change data on the displayed Configuration Page, press the small right knob
(CRSR) to turn on the cursor. Rotate the large right knob to change between data
fields. Rotate the small knob to change a field that the cursor is on. Once you have
made the desired selection, press the ENT key to accept the entry.
Use the small knob to reach the MAIN RS232 CONFIG page
Select the CHNL number that matches the pin Echo is wired to example pin 41=
Out 3
Select ADS-B+ for the Output Value
Press Enter
Power the GNS Off and then On