26
UAV-1001006-001
ECCN 7A994
See Table below for custom configurations
•
COM1 Protocol
o
Typically N/A
See Table below for custom configurations
•
COM2 Rate
o
115,200 if connected using SkyFYX GPS
See table below for other other GPS configurations
•
COM2 Protocol
o
NMEA if using SkyFYX GPS
See table below for other GPS Configurations
Other GPS Serial Receive Port 2 (Com 2) configurations.
Equipment
COM2 Rate
COM2 Protocol
Safe Fly 2020 direct
connect
115200
NMEA
Accord Micro-i
115200
NMEA
Garmin GPS-20A
9600
ADS-B+
Garmin GNS
4xxW/5xxW/6xxW/7xxW
9600
ADS-B+
8.3.1 Custom Serial Port Setup
The following parameters configure the echoUAT to interface with a
supported with supported devices. The Appendices in this document
define the specifics of a particular device interface configurations.
Supported Parameters
Parameter Source
Port
Baud
Rate
Data
Interface
Protocol
SETUP
APP
NA
NA
NA
NA
NA
Serial 1
(COM1)
COM1 PROG
PROG
PROG
PROG
CONTROL Serial 1
(COM1)
COM1 PROG
PROG
PROG
PROG
XPDR
MONITOR
NA
NA
NA
NA
NA
GPS
Serial 1
(COM1)
COM1 PROG
PROG
PROG
PROG
Serial 2
(COM2)
COM2 PROG
PROG
PROG
PROG
Содержание echoUAT
Страница 1: ...1 UAV 1001006 001 ECCN 7A994 Installation and User Guide ...
Страница 30: ...30 UAV 1001006 001 ECCN 7A994 1 Appendix A Interconnect Diagrams ...
Страница 31: ...31 UAV 1001006 001 ECCN 7A994 ...
Страница 32: ...32 UAV 1001006 001 ECCN 7A994 ...
Страница 33: ...33 UAV 1001006 001 ECCN 7A994 ...
Страница 38: ...38 UAV 1001006 001 ECCN 7A994 GRT Example Wiring ...
Страница 39: ...39 UAV 1001006 001 ECCN 7A994 ...