background image

ii

IMPORTANT SAFETY INSTRUCTIONS

to reduce the risk of fire, electric shock, or injury when using your air cleaner, follow these basic precautions:

SAFETY PRECAUTIONS

We have provided many important safety messages in this manual on your SMoGHoG SHM. always read and obey 

all safety messages.

•  Wear protective clothing and safety glasses when handling 

collector components or servicing the unit.

•  Use proper lifting and rigging equipment to install your 

 

mist collector (or unit)

• Disconnect power before servicing.
• Replace all access panels before operating.
• Do not operate the unit with component doors open.
•  Electrical connections should only be made by qualified 

 

personnel and be in accordance with local and national 

codes and regulations.

•  Do not use in explosive atmospheres.
• Do not collect emissions which are explosive.
•  Keep flammable materials and vapors, such as gasoline, 

away from the unit.

•  The unit should be inspected frequently and contaminants 

removed to prevent excessive accumulation which may 

result in flash-over or fire damage.

• Operate only in a safe and serviceable condition.
•  Operating temperature to the air stream should not 

 

exceed 120° F (49° C).

!

 

 

!

   

D A N G E R

!

 

WARNING

!

 

WARNING

!

 

 

C A U T I O N

C A U T I O N

this is the safety alert symbol.
this symbol alerts you to potential hazards that can kill or hurt you and others. all safety messages will follow the 

safety alert symbol and the word “danGer” “WarninG” or “caution”. these words mean:

Indicates a hazardous situation which, if not avoided, will result in death or 

serious injury.

Indicates a potentially hazardous situation which, if not avoided, could result

in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, may result

in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially

hazardous situation which, if not avoided, may result in property damage.

Содержание SMOGHOG SHM-C Series

Страница 1: ...Model SHM 11C Shown SMOGHOG Media Mist Collector l Models SHM C SHM F OWNER S MANUAL...

Страница 2: ...following information available when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL _____________________________________________________________...

Страница 3: ...n 8 3 6 1 Installation Procedure for After Filters 8 3 6 1 1 Hold Down 8 3 6 1 2 Enclosed 10 3 7 Drains 10 4 UNIT OPERATION 10 4 1 Start up 10 4 2 System Operation 10 4 2 1 Airflow Adjustment Using Ma...

Страница 4: ...erials and vapors such as gasoline away from the unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulation which may result in flash over or fire damage O...

Страница 5: ...e assistance in the installation startup operation maintenance or troubleshooting of your air cleaning equipment contact your local UAS sales representative 2 1 SMOGHOG NOMENCLATURE SMOGHOG oil mist a...

Страница 6: ...REV 16I SMOGHOG SHM Series Models 2 FIGURE 1B SHM Equipment Description 61 10113 FIGURE 1A SHM Equipment Description...

Страница 7: ...the unit in each corner Do not lift the unit by placing lift truck forks through the legs on the underside of the unit Filter Elements Stage 1 Mist Stop fine fiber aluminum mesh Stage 2 Primary coale...

Страница 8: ...ering drawings of your specific equipment and options will be provided These and all available documentation for your system should be thoroughly reviewed prior to beginning any installation work This...

Страница 9: ...guration Secure the unit at all four corners using the standard unit feet or extension leg foot pads At least one of the two holes per foot pad on the extension legs should be secured See Figure 1 for...

Страница 10: ...S ON SHM 11 SUBTRACT 0 5 AMP FROM FLA VALUES ABOVE TABLE 2 Wire Diagrams 3 5 1 ELECTRICAL SUPPLY POWER The main power supply is connected to the SHM unit through a 1 FNPT coupling located on the rear...

Страница 11: ...REV 16I SMOGHOG SHM Series Models 7 61 10126 Figure 4 Remote Panel Touchscreen Connection...

Страница 12: ...INTERLOCK DRY CONTACT The customer has the option to control the SHM On Off operation with the oil mist generating equipment or process This will allow the operator to control the SHM with a dry conta...

Страница 13: ...REV 16I SMOGHOG SHM Series Models 9 61 10115 Figure 5B SHM Filter Removal Installation Figure 5A SHM Filter Removal Installation...

Страница 14: ...other equipment will need to be engaged as well 7 Verify performance of the system by measuring airflow or evaluating capture at each collection point It is recommended to record baseline performance...

Страница 15: ...fter Filter monitoring or unique screens required for a special application These screens are based on customer order and loaded at the factory Figure 6 4 3 2 Standard Format The icon key Table 3 outl...

Страница 16: ...arrows The second method of airflow adjustment is to touch the box that shows the percentage of the airflow A number pad will be shown in a pop up screen You can enter any number between 20 and 100 T...

Страница 17: ...re not password protected To select one of the items just touch the box with the item you want to make a change too The Locked Settings selection will allow the operator to select options of the syste...

Страница 18: ...cked Settings group on the Customer settings screen The Auto Flow is an option that is selected at order time and loaded into the SHM at the factory The Auto Flow Settings will allow the unit to maint...

Страница 19: ...r hose This filter can be replaced if contaminants become impossible to remove or due to excessive wear Always wear proper PPE including goggles dust mask and work gloves when installing or replacing...

Страница 20: ...into place prior to hanging the individual bags loops For units that are two filters deep be sure to push the first filter all way toward the back of the primary filter cabinet until it contacts the...

Страница 21: ...ker Open rear panel on unit and switch breaker if necessary Loose or disconnected wires Inves gate wiring in the rear panel Disconnect is switched to OFF posi on Switch disconnect to ON posi on Improp...

Страница 22: ...LTER HEPA 99 97 0 3 m 5 33 10117 ALUMINUM MESH PRE FILTER 6 33 10128 COALESCING CARTRIDGE FILTER 9 OD PEACH MEDIA 33 LENGTH 3 33 10129 CABINET AFTER FILTER MICROGUARD O M 95 0 3 m 7 39 10008 0006 CONT...

Страница 23: ...REV 16I SMOGHOG SHM Series Models 19 Figure 6 SHM Replacement Parts SHM 11C SHM 11F...

Страница 24: ...REV 16I SMOGHOG SHM Series Models 20 APPENDIX WIRING DIAGRAMS BASIC CONTROLS A1 04 001682...

Страница 25: ...REV 16I SMOGHOG SHM Series Models 21 A2 REMOTE PANEL BASIC CONTROLS 04 001799...

Страница 26: ...REV 16I SMOGHOG SHM Series Models 22 A3 ONE BLOWER AND CONTROLS 04 001695...

Страница 27: ...REV 16I SMOGHOG SHM Series Models 23 A4 TWO BLOWER AND CONTROLS 04 001696...

Страница 28: ...REV 16I SMOGHOG SHM Series Models 24 A5 THREE BLOWER AND CONTROLS 04 001697...

Страница 29: ...REV 16I SMOGHOG SHM Series Models 25 A6 REMOTE PANEL TOUCH CONTROLS 04 001802...

Страница 30: ...REV 16I SMOGHOG SHM Series Models 26 A7 ONE BLOWER AND REMOTE CONTROLS 04 001798...

Страница 31: ...REV 16I SMOGHOG SHM Series Models 27 A8 TWO BLOWER AND REMOTE CONTROLS 04 001797...

Страница 32: ...REV 16I SMOGHOG SHM Series Models 28 A9 THREE BLOWER AND REMOTE CONTROLS 04 001796...

Страница 33: ...REV 16I SMOGHOG SHM Series Models 29 A10 575 480 TRANSFORMER 04 001717...

Страница 34: ...This page intentionally left blank...

Страница 35: ...This page intentionally left blank...

Страница 36: ...anty as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a written instrument signed by the President or Vice...

Отзывы: