4.3.5 AFTER-FILTER
Figure 11
When the screen is active you will see the differential
pressure across the filter. the system will monitor this
pressure and give warnings and faults as the differential
pressure changes. the after-filter does not get cleaned by
the system and has a finite life based on the pressure drop
across the filter. When the pressure drop increases to a
point that the filter can no longer provide proper airflow,
the fault symbol will appear. you will need to replace the
filter at that time.
4.3.6 CUSTOMER SETTINGS
the standard customer settings screen shown in
figure 12 will allow the operator to make General Settings
changes without a password. the Locked Settings will
require a password to be entered. the default password is
4440.
Figure 12
the General Settings selection will allow the operator
to change the units and check service of the major
components like the blower. these settings are not
password protected. to select one of the items just touch
the box with the item you want to make a change too.
the Locked Settings selection will allow the operator
to select options of the system. one option is Machine
interlock. With Machine interlock the operator can allow
another device (cnc machine center, plasma table, or
weld machine) to turn the SHM on when the primary
device is in operation. When this option is selected (see
figure 20) the Blower Power button in figure 6 will put
the unit in standby when touched by the operator. When
this setting is selected the indicator to the right side will
change from off to on and turn green.
Figure 13
When After‐Filter and/or Auto‐Flow options are ordered,
they will appear on the customer Settings screen as
shown on figure 13.
Figure 14
When the units selection is made on the customer Settings
screen, you will see the screen as shown on figure 14.
Figure 15
the operator can select the Service settings shown here.
each of the selection will allow the operator to see the
health of the unit. you are also able to see any pending
alarms and the alarm history for your system using the
buttons provided.
Содержание SMOGHOG SHM-C Series
Страница 1: ...Model SHM 11C Shown SMOGHOG Media Mist Collector l Models SHM C SHM F OWNER S MANUAL...
Страница 11: ...REV 16I SMOGHOG SHM Series Models 7 61 10126 Figure 4 Remote Panel Touchscreen Connection...
Страница 23: ...REV 16I SMOGHOG SHM Series Models 19 Figure 6 SHM Replacement Parts SHM 11C SHM 11F...
Страница 24: ...REV 16I SMOGHOG SHM Series Models 20 APPENDIX WIRING DIAGRAMS BASIC CONTROLS A1 04 001682...
Страница 25: ...REV 16I SMOGHOG SHM Series Models 21 A2 REMOTE PANEL BASIC CONTROLS 04 001799...
Страница 26: ...REV 16I SMOGHOG SHM Series Models 22 A3 ONE BLOWER AND CONTROLS 04 001695...
Страница 27: ...REV 16I SMOGHOG SHM Series Models 23 A4 TWO BLOWER AND CONTROLS 04 001696...
Страница 28: ...REV 16I SMOGHOG SHM Series Models 24 A5 THREE BLOWER AND CONTROLS 04 001697...
Страница 29: ...REV 16I SMOGHOG SHM Series Models 25 A6 REMOTE PANEL TOUCH CONTROLS 04 001802...
Страница 30: ...REV 16I SMOGHOG SHM Series Models 26 A7 ONE BLOWER AND REMOTE CONTROLS 04 001798...
Страница 31: ...REV 16I SMOGHOG SHM Series Models 27 A8 TWO BLOWER AND REMOTE CONTROLS 04 001797...
Страница 32: ...REV 16I SMOGHOG SHM Series Models 28 A9 THREE BLOWER AND REMOTE CONTROLS 04 001796...
Страница 33: ...REV 16I SMOGHOG SHM Series Models 29 A10 575 480 TRANSFORMER 04 001717...
Страница 34: ...This page intentionally left blank...
Страница 35: ...This page intentionally left blank...