17
INSTALLATION
INSTALLATION IN TO A FACTORY BUILT (METAL) FIREPLACE
When installing into a factory built
fi
replace, the
fi
rebox must accept the insert without modi
fi
cation other than removing
bolted or screwed together pieces such as smoke shelf/de
fl
ectors, ash lips, screen or door tracks and damper assemblies.
These items must be reinstalled to restore the
fi
replace to its original operating condition if the insert is removed and not
replaced. The removal of any part must not alter the integrity of the listed
fi
replace in any way.
The factory built
fi
replace must be listed per UL 127. Installation must include a full height listed chimney liner meeting
type HT requirements (2100o F) per 1777 (U.S.). The liner must be securely attached to the insert
fl
ue collar and the
chimney top. The damper area must be sealed to prevent room air passage to chimney cavity.
Alteration of the
fi
replace in any manner is not permitted except with the following exceptions:
•
External trim pieces, which do not affect the operation of the
fi
replace, may be removed proving they can be stored
on or within, the
fi
replace for re-assembly if the insert is removed.
• The
fi
replace damper may be removed to install the chimney liner.
Circulating air chambers, louvers or cooling air inlet or outlet ports (i.e. in a steel
fi
replace liner or metal heat circulator)
shall not be blocked.
Means must be provided for removal of the insert to clean the chimney
fl
ue.
A permanent metal warning label must be attached to the back wall of the
fi
replace opening stating the following:
• “This
fi
replace has been altered to accommodate a
fi
replace insert and should be inspected by a quali
fi
ed person
prior to re-use as a conventional
fi
replace.”
•
This label is available upon request.
Final approval is contingent on the authority having jurisdiction.
VERTICAL CAP
STORM COLLAR
COVER PLATE
(NON-COMBUSTIBLE)
SEAL WITH SILICONE.
3 OR 4 INCH L-VENT
OR STAINLESS STEEL
FLEXIBLE OR SINGLE
WALL PIPE
THE SMOKE SHELF
MAY BE REMOVED
10”
THE DAMPER MAY
BE REMOVED
INTERNAL BAFFLES
MAY BE REMOVED
TO PREVENT FIREPLACE
ODORS FROM ENTERING
THE HOME, PAINT THE
INTERIOR OF THE FIREPLACE
WITH LATEX PAINT
THE METAL SIDES, FRAME MEMBERS, OR OTHER
STRUCTURAL COMPONENTS OF THE FACTORY BUILT
FIREPLACE MAY NOT BE REMOVED OR ALTERED
USE THE ZERO-CLEARANCE
SKIRT TO SUPPORT THE
INSERT ON RAISED FIREPLACES
THE MASONRY LINING
MAY NOT BE REMOVED
NOTE:
THE LOG SHELF, SCREEN,
AND DOORS (IF PRESENT)
MUST BE REMOVED
FIGURE 16
Содержание Ashley AP5770