IMPORTANT SAFETY INSTRUCTIONS

This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and of

fi

 ces other than 

normal residential housekeeping purposes.
When using any electrical appliance, basic precautions should always be followed, including the following:

NOTE

: Read all instructions before using this machine.

 WARNING!

To reduce the risk of 

fi

 re, electric shock, or injury:

 

Do not leave the machine unattended when it is plugged in.  Unplug the unit from the outlet when not in use and before 
servicing.

 

To avoid electric shock, do not expose to rain or snow.  Store, and use, indoors.

 

Do not allow to be used as a toy.  Close attention is necessary when used near children.

 

Use only as described in this manual.  Use only the manufacturer’s recommended attachments.

 

Never add water over 130º F/54º C to the solution tank.

 

Do not use with damaged cord or plug.  If the machine is not working as it should, has been dropped, damaged, left outdoors or 
dropped into water, return it to a service center.

 

Do not pull by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners.  Do 
not run the machine over the cord.  Keep the cord away from heated surfaces. To unplug, grasp the plug, not the cord.

 

Do not handle the plug, the cord or the machine with wet hands.

 

Extension cords must be 12/3 and no longer than 50 feet.  Replace the cord or unplug immediately if the ground prong becomes 
damaged.

 

Do not put any object into openings.  Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may 
reduce air 

fl

 ow.

 

Keep loose clothing, hair, 

fi

 ngers, and all parts of body away from openings and moving parts.

 

Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes, or any health endangering dusts.  
Do not use to pick up 

fl

 ammable or combustible liquids such as gasoline or use in areas where they may be present.

 

Turn off all controls before unplugging.

 

Use extra care when cleaning on stairs.

 

Connect to a properly grounded outlet only.

 

Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure,or chemical content.

 

Use a respirator and gloves when using dry cleaning solvents.  In addition, a fan or blower is helpful to blow fumes away from 
the operator.

 

Always work in a well ventilated area.

 

Always work with the exhaust hose attached to the machine when using solvents.

SAVE THESE INSTRUCTIONS

revised 6/12

12/10

A - 3

 56041875 - PB111

ENGLISH - A 

INSTRUCTIONS FOR USE

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание PB111-120

Страница 1: ...lution out of the solution tank and empty the recovery bucket after each job 9 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors Do not us...

Страница 2: ...n so that it can be inspected CLEANING SOLUTIONS The PB111 is capable of either wet or dry cleaning Only liquid cleaners are recommended no powders Solvents with a flash point of 140 F or higher are r...

Страница 3: ...rom heated surfaces To unplug grasp the plug not the cord Do not handle the plug the cord or the machine with wet hands Extension cords must be 12 3 and no longer than 50 feet Replace the cord or unpl...

Страница 4: ...ect this plug to a 2 pole receptacle as shown in Figure 2 if a properly grounded outlet is not available The temporary adapter should be used only until a properly grounded outlet Figure 1 can be inst...

Страница 5: ...of the bucket Reinstall the recovery bucket and the dome 7 Make sure the float in the bucket travels freely up and down the rod each time you empty the recovery bucket TO SWITCH CHEMICAL BASE 8 When...

Страница 6: ...CT BRASS FITTINGS AFTER USING THE BOOSTER HEAT THE FITTINGS CAN GET VERY HOT AND MAY CAUSE MINOR BURNS AUTO VAC SHUT OFF When the recovery bucket is full the vacuum motor will automatically shut off T...

Страница 7: ...ther there is solvent or water base cleaning in holding tank Patented Unique fail safe system automatically prevents solvent from heating above 140 F regardless of heat setting Pump Centrifugal type 4...

Страница 8: ...9 10 11 12 13 14 15 16 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 9 44 6 D 2 PB111 56041875 1 10 PARTS LIST h t t p s h a r r i s s u p p l y i n d c o m T o O r d...

Страница 9: ...1 240 FP654 1 Power Cord 300 240V model PB111 240 32 76A 1 Hose Clamp Ss 1 13 16 X 2 3 4 33 FP247 1 Repair Kit PB111 Heat System 34 SUB459 4 Louver 2 1 2 Grey Plastic W 35 FP440 1 Body Black Ultimate...

Страница 10: ...6 Screw 1 4 20 X 1 2 Hwh Sl 5 4 Caster For Ultimate Chrome NOTE 1 6 1 Caster Plate Plastic Polypropi NOTE 1 7 SUB928 2 Louver 3 Grey Plastic Include NOTE 1 These items are not available for sale separ...

Страница 11: ...Ms 7 429 1 Plate Heat Sink 8 447 1 Circuit Board 120 V Solvent all models except PB111 240 448 1 Circuit Board Solvent Sense model PB111 240 9 138A 1 Bolt Hex Ss 1 4 20x1 3 4 10 409A 1 Relay Solid St...

Страница 12: ...models except PB111 240 includes 1 2 12 FP186 1 Pump Motor PB111 240V No Me model PB111 240 includes 1 2 12 12 435B 1 Pump Slide Bracket Male 13 SUB405 1 Pump Head Brass For Pb111 120 14 56478523 1 Ti...

Страница 13: ...asher Flat Ss 10 6 33 1 Screw Bhs Brass 10 32x3 8 Ms 7 129 1 Bushing Zinc 4 40 X 1 2 8 131 2 Bushing Aluminum 10 32 X 1 9 145 1 Insert 531 X 1 4o D X 10 32 10 420 1 Handle Bucket Ss 3 16 11 421USP 1 R...

Страница 14: ...3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 VACUUM CHAMBER ASSY revised 6 12 D 8 PB111 56041875 1 10 PARTS LIST h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0...

Страница 15: ...Tape Cloth 2 X 60 Yds Bla 10 123USP 1 Reed Switch 5 16 24 X 1 1 11 156USP 2 Hose Clamp Size 28 1 9 16 2 1 2 12 19USP 3 Screw 4 40 X 3 4 Flathead 13 419USP 1 Gasket Ccns Psa 4 Idx1 2 Thick 14 FP163 1...

Страница 16: ...OLUTION TANK ASSY revised 6 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 D 10 PB111 56041875 1 10 PARTS LIST h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Страница 17: ...Ss Zp 1 4 20 9 137 2 Washer Slitlock Ss Zp 1 4 10 425 11 5 Gasket 40 Shore Santoprene 11 425 21 Gasket 40 Shore Santoprene 12 426 1 Cover Pump 13 FP246 1 Solution Tank S S For PB111 Co 14 454 42 Pin...

Страница 18: ...h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Страница 19: ...h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Страница 20: ...2 0133 800 257 7982 FAX 425 322 0136 11015 47th Ave W Mukilteo WA 98275 VISIT US AT http www usproducts com h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8...

Отзывы: