background image

OPERATION

REFER TO THE DIAGRAMS ON THE PREVIOUS PAGE

HIGH PRESSURE WASHER

1

Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness.

Make sure hoses are in good condition and the spray nozzle(s) is tight.

REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON THE FOLLOWING PAGES

2. Connect the dump hose to the back of the machine, and place the open end of the hose in a drain.

Make sure the recovery tank drain hose is closed and that the lid is screwed on tight.

3. If you choose to use the auto-fill feature, connect the fill hose to the autofill valve (located over the

solution tank fill hole.  Place your gallon of chemical in the chemical basket on the recovery tank lid, and

put the weighted foot valve into the gallon. Turn on the water source, and allow the tank to fill with

solution.  When using the auto-fill system, the auto fill valve will automatically turn on and turn off as the

tank empties and then fills.  NOTE: If you are not going to use the auto-fill system, just fill the tank with

water and cleaning chemical.  Follow chemical directions regarding dilution and mixing.  Do not use harsh

chemicals; they may damage seals in pumps and valves, and cause the pump to wear prematurely.

NOTE: using warm water in the tank may improve the efficiency of the heat exchanger when cleaning
with heat, but never use water with a temerature exceeding 54ºC/130ºF.

4. Pre-spray the area to be cleaned, with a pump-up sprayer, while the tank is filling.  Follow chemical

directions.

5. Connect the solution hose (from the reel) to the 1200 PSI Quick Disconnect on the front of the tank,

below the switch plate.  Refer to illustration on page 3.

6. Plug in the two power cords.  Do not connect both cords to the same outlet.  Although all systems

on the high pressure side of the machine may work correctly if you are not on two circuits, a circuit

breaker in a wall panel may trip.

Turn on the high pressure pump by placing the HIGH PRESSURE/HEAT selection switch (2) in the UP

position, to select the High Pressure Pump.  NOTE: The high pressure pump and the heat can not

operate at the same time.   NOTE: this switch is off when it is set to the middle position and neither the

high pressure pump or the heater is selected.

7. Prime the 1200 psi pump using the ‘power prime’ system: turn on both the pump and the vacuum,

cover the hole in the hose barb with your hand, then depress the Power Prime Pedal. This will pull trapped

air through the pump and into the recovery tank

 

, priming the pump.  You will notice a ‘tone’ change from

the pump (smoother, with less of a rattle), and the water being pulled into the recovery tank will change

to a clear, solid stream.  Priming may take 20 - 60 seconds and will require a full solution tank.  When

the pump is primed, let off the Power Prime Pedal, and turn off the pump and the vacuum.  Depress

the Power Prime Pedal once again, for a moment, to release the line pressure. Proceed to the next step.

8. Add defoamer to the recovery tank.

9. Attach the solution spray hose to the solution quick disconnect.  Attach the vacuum hose to the hose barb

on the front of the recovery tank.  Pull the hoses out from the reel.  Attach the other ends of the hoses

to the cleaning tool.

10. Turn on the vacuum (3) and turn on the dump pump (5). Begin spraying.  NOTE: the dump pump will

automatically turn on and turn off as the tank fills and then empties (refer to drawings on page 8).

11. When the job is finished, turn off the water source.  Vacuum the remaining solution from the holding tank

into the recovery tank.

12. Run a few gallons of clean water through the system.  Completely drain the recovery tank by placing the

dump hose over a drain, or a bucket, and removing the cap.  Disconnect the hoses from the cleaning

tool, and reel them up onto the hose spool.

13. Unplug the power cords.

14. Clean the machine and the tool.

CAUTION

:  Use care when handling hazardous chemicals.

CAUTION

:  Never leave the 1200 psi pump running when you are not actively using it.

DANGER:  

Do NOT use solvents, or any chemicals that may be flammable, explosive

or combustible.

5

Содержание KC-1200 PRO 240V

Страница 1: ...ts 2 Never allow the spray to remain fixed in one spot 3 Before each use remove the spray tool from the hose and check to make sure the spray nozzle is securely tightened to the spray tool A loose noz...

Страница 2: ...d into water return it to a service cen ter Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cor...

Страница 3: ...rformance flush the machine with clear water at the end of each working day Once a month minimum run a flushing compound through the machine to break up any mineral or chemical build up that may have...

Страница 4: ..._____________ Model KING COBRA 1200 PRO 240V Purchase Date _____________ Write the name and phone number of your distributor _____________________________________ 4 SWITCH PLATE 5 HIGH PRES SURE PUMP...

Страница 5: ...mp by placing the HIGH PRESSURE HEAT selection switch 2 in the UP position to select the High Pressure Pump NOTE The high pressure pump and the heat can not operate at the same time NOTE this switch i...

Страница 6: ...into separate circuits Although all systems in the machine may work correctly if you are not on two circuits a circuit breaker in a wall panel may trip 6 Press the power prime pedal located on the rea...

Страница 7: ...S THAT MAY BE FLAMMABLE EXPLOSIVE OR COMBUSTIBLE 3 Operation Attach a 3 4 garden hose to the autofill valve and connect the other end of the hose to your water source Make sure the float that hangs fr...

Страница 8: ...ny chemical residue Remove and clean the stainless steel filter in the back of the tank Reinstall the filter once it is clean Clean and empty the recovery tank DANGER DO NOT USE SOLVENTS OR ANY CHEMIC...

Страница 9: ...9 240V...

Страница 10: ...r 3 includes screws 98 1278 Hose heatertooutlet 99 1329 Hose Assembly 26 bypass 100 925 Hose 3 8 X 45 pump to heater 101 141 Coupling 1 4 fpt both ends 102 152 T brass 1 4 npt 104 1159A Pump motor com...

Страница 11: ...nd Weight Dimensions Lifetime Warranty 7 2 3 stage Ball Float Positive displacement fully adjustable 0 500 psi Positive displacement 1200 psi 2 2 gpm 140 Instant to 212 F 2000 Watts Stainless steel si...

Страница 12: ...KC 1200 PRO 240V DUAL SURFACE EXTRACTOR 208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com NOTES 12...