Record the serial number and model of your new extractor here:
(and be sure to mail your warranty card)
Serial Number: __________________
Model: COBRA PLUS-300
Purchase Date:_____________
Write the name and phone number of your distributor:
_____________________________________
_____________________________________
1
Inspect the machine, hoses, and cleaning tools for cleanliness and completeness.
2
Fill the solution tank with water. Using warm water may be a benefit in cleaning effectiveness,
but do not use hot water (above 130
°
F / 54
°
C) in the tank.
3
Plug in the power cords. Do not connect both cords to the same outlet; the green, circuit locator light
on the switch plate should light up. If the locator light does not come on, try different outlets with one
of the cords until it does. If you are certain the cords are on separate circuits, turn the Bypass switch
on.
CAUTION: using the Bypass switch when the cords are on the same circuit may cause the breaker in
the wall to trip. NOTE: the receptacle on the left (viewed from behind the machine) powers the heater.
The red light will turn on only when the heat exchanger is actively heating.
4
Connect the priming hose to the machine, turn the pump ON by turning the pump pressure knob up to
OPERATION
PUMP
PRESSURE
ADJUST
TEMPERATURE
ADJUST
CIRCUIT LOCATOR
LIGHT INDICATES
TWO CIRCUITS.
HEATER WILL
AUTOMATICALLY
TURN ON
BYPASS SWITCH.
TURNS THE HEATER
ON WHEN GREEN
LIGHT IS NOT ON
1
2
3
VACUUM
ON/OFF
SWITCH
4
5
6
INDICATES
SPRAYING
PRESSURE
PRESSURE
GAUGE
7
RED LIGHT INDICATES
HEATER IS HEATING
SWITCH PLATE
Содержание COBRA PLUS-300
Страница 6: ......